OMSimulator -r=Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.AHUs.MultiZone.VAV.SetPoints.Validation.FreezeProtection_res.mat --tempDir=temp_Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_AHUs_MultiZone_VAV_SetPoints_Validation_FreezeProtection_fmu --startTime=0 --stopTime=3600 --timeout=50 --tolerance=1e-06 Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_AHUs_MultiZone_VAV_SetPoints_Validation_FreezeProtection.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_AHUs_MultiZone_VAV_SetPoints_Validation_FreezeProtection_fmu" info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.AHUs.MultiZone.VAV.SetPoints.Validation.FreezeProtection/temp_Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_AHUs_MultiZone_VAV_SetPoints_Validation_FreezeProtection_fmu" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.AHUs.MultiZone.VAV.SetPoints.Validation.FreezeProtection" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.AHUs.MultiZone.VAV.SetPoints.Validation.FreezeProtection/temp_Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_AHUs_MultiZone_VAV_SetPoints_Validation_FreezeProtection_fmu/model-8k9w75pc" info: maximum step size for 'model.root': 0.100000 info: No result file will be created warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11: The following assertion has been violated at time 2763.636364 not frePro.lat2.y assert | warning | Warning: minimum ventilation was interrupted by freeze protection! warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11: The following assertion has been violated at time 3345.454545 not frePro.lat1.y assert | warning | Warning: the unit is shut down by freeze protection! info: Final Statistics for 'model.root': NumSteps = 1903 NumRhsEvals = 1965 NumLinSolvSetups = 131 NumNonlinSolvIters = 1964 NumNonlinSolvConvFails = 0 NumErrTestFails = 14 info: 2 warnings info: 0 errors