Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildSysPro_BuildSysPro.Systems.HVAC.Production.Boiler.Boiler.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0-master/package.mo", uses=false) Using package BuildSysPro with version 3.5.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0-master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(BuildSysPro.Systems.HVAC.Production.Boiler.Boiler,fileNamePrefix="BuildSysPro_BuildSysPro_Systems_HVAC_Production_Boiler_Boiler",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(BuildSysPro.Systems.HVAC.Production.Boiler.Boiler,fileNamePrefix="BuildSysPro_BuildSysPro_Systems_HVAC_Production_Boiler_Boiler",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001319/0.001318, allocations: 92.08 kB / 15.06 MB, free: 1.098 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001672/0.001673, allocations: 172.7 kB / 15.95 MB, free: 208 kB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.616/1.616, allocations: 223.3 MB / 240 MB, free: 5.422 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0-master/package.mo): time 1.193/1.193, allocations: 143.4 MB / 434.4 MB, free: 13.76 MB / 350.1 MB Notification: Performance of FrontEnd - loaded program: time 0.0004578/0.0004582, allocations: 8 kB / 0.5161 GB, free: 11.21 MB / 430.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2319/0.2324, allocations: 83.42 MB / 0.5975 GB, free: 7.73 MB / 0.4981 GB Notification: Performance of NFInst.instantiate(BuildSysPro.Systems.HVAC.Production.Boiler.Boiler): time 0.002837/0.2353, allocations: 1.928 MB / 0.5994 GB, free: 5.789 MB / 0.4981 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0-master/BaseClasses/Media/OLD_THERMHYGAERO/AirFunctions/Psat.mo:3:3-3:24:writable] Error: Invalid public variable AH, function variables that are not input/output must be protected. Notification: Performance of FrontEnd: time 0.001081/0.2364, allocations: 455 kB / 0.5998 GB, free: 5.344 MB / 0.4981 GB