OMSimulator --tempDir=temp_AixLib_latest_AixLib_Fluid_DistrictHeatingCooling_Supplies_Examples_DHCSupplyHeaterCoolerStorage_fmu --startTime=0 --stopTime=172800 --timeout=50 --tolerance=1e-05 AixLib_latest_AixLib_Fluid_DistrictHeatingCooling_Supplies_Examples_DHCSupplyHeaterCoolerStorage.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_AixLib_latest_AixLib_Fluid_DistrictHeatingCooling_Supplies_Examples_DHCSupplyHeaterCoolerStorage_fmu" info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_latest_AixLib.Fluid.DistrictHeatingCooling.Supplies.Examples.DHCSupplyHeaterCoolerStorage/temp_AixLib_latest_AixLib_Fluid_DistrictHeatingCooling_Supplies_Examples_DHCSupplyHeaterCoolerStorage_fmu" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_latest_AixLib.Fluid.DistrictHeatingCooling.Supplies.Examples.DHCSupplyHeaterCoolerStorage" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_latest_AixLib.Fluid.DistrictHeatingCooling.Supplies.Examples.DHCSupplyHeaterCoolerStorage/temp_AixLib_latest_AixLib_Fluid_DistrictHeatingCooling_Supplies_Examples_DHCSupplyHeaterCoolerStorage_fmu/model-2ibsk442" warning: fmu (logStatusWarning): The following assertion has been violated at time 0.000000 (if substation2.jun1.res2.m_flow_nominal_pos > 1e-15 then substation2.jun1.res2.m_flow_nominal_pos else 1.0) >= -100000.0 and (if substation2.jun1.res2.m_flow_nominal_pos > 1e-15 then substation2.jun1.res2.m_flow_nominal_pos else 1.0) <= -0.0 assert | warning | Nominal variable violating min/max constraint: -100000.0 <= $cse92 <= -0.0, has value: 5 warning: fmu (logStatusWarning): The following assertion has been violated at time 0.000000 (if substation2.jun1.res3.m_flow_nominal_pos > 1e-15 then substation2.jun1.res3.m_flow_nominal_pos else 1.0) >= -100000.0 and (if substation2.jun1.res3.m_flow_nominal_pos > 1e-15 then substation2.jun1.res3.m_flow_nominal_pos else 1.0) <= -0.0 assert | warning | Nominal variable violating min/max constraint: -100000.0 <= $cse93 <= -0.0, has value: 5 warning: fmu (logStatusWarning): The following assertion has been violated at time 0.000000 (if substation1.jun1.res2.m_flow_nominal_pos > 1e-15 then substation1.jun1.res2.m_flow_nominal_pos else 1.0) >= -100000.0 and (if substation1.jun1.res2.m_flow_nominal_pos > 1e-15 then substation1.jun1.res2.m_flow_nominal_pos else 1.0) <= -0.0 assert | warning | Nominal variable violating min/max constraint: -100000.0 <= $cse105 <= -0.0, has value: 5 warning: fmu (logStatusWarning): The following assertion has been violated at time 0.000000 (if substation1.jun1.res3.m_flow_nominal_pos > 1e-15 then substation1.jun1.res3.m_flow_nominal_pos else 1.0) >= -100000.0 and (if substation1.jun1.res3.m_flow_nominal_pos > 1e-15 then substation1.jun1.res3.m_flow_nominal_pos else 1.0) <= -0.0 assert | warning | Nominal variable violating min/max constraint: -100000.0 <= $cse106 <= -0.0, has value: 5 warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348: The following assertion has been violated during initialization at time 0.000000 substation1.pumHeaPri.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348: The following assertion has been violated during initialization at time 0.000000 substation1.pumCoo.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348: The following assertion has been violated during initialization at time 0.000000 substation2.pumHeaPri.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348: The following assertion has been violated during initialization at time 0.000000 substation2.pumCoo.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. info: maximum step size for 'model.root': 0.100000 info: Result file: model_res.mat (bufferSize=10) [CVODE ERROR] CVode At t = 99.81, mxstep steps taken before reaching tout. error: [stepUntil] SUNDIALS_ERROR: CVode() failed with flag = -1 assert | debug | New end position is not bigger then previous last node. error: [fmi2logger] fmu (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_import_completed_integrator_step failed for FMU "model.root.fmu" assert | debug | New end position is not bigger then previous last node. error: [fmi2logger] fmu (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable substation2.vol1.wrongEnergyMassBalanceConfiguration stdout | error | x got reinitialized during an event at time 99.810001. OpenModelica can't handle that.