Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.Merkel.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/package.mo", uses=false) Using package Buildings with version 11.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.Merkel,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|TEnt.T|tow.TLvg|tow.TAir|conFan.u_s|conFan.u_m|onOffCon.u|onOffCon.reference",fileNamePrefix="Buildings_latest_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.Merkel") translateModel(Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.Merkel,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|TEnt.T|tow.TLvg|tow.TAir|conFan.u_s|conFan.u_m|onOffCon.u|onOffCon.reference",fileNamePrefix="Buildings_latest_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.Merkel") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.00106/0.00106, allocations: 102.6 kB / 15.71 MB, free: 460 kB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.00136/0.00136, allocations: 176.2 kB / 16.58 MB, free: 6.863 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.546/1.546, allocations: 223.2 MB / 240.6 MB, free: 5.355 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/package.mo): time 2.862/2.862, allocations: 436.7 MB / 0.7113 GB, free: 7.82 MB / 0.5606 GB Notification: Performance of FrontEnd - loaded program: time 0.0003695/0.0003695, allocations: 12 kB / 0.8717 GB, free: 4.77 MB / 0.7169 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.9488/0.9491, allocations: 153.7 MB / 1.022 GB, free: 1.141 MB / 0.7637 GB Notification: Performance of NFInst.instantiate(Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.Merkel): time 0.2586/1.208, allocations: 218.4 MB / 1.235 GB, free: 6.172 MB / 0.9825 GB Notification: Performance of NFInst.instExpressions: time 1.001/2.209, allocations: 25.17 MB / 1.26 GB, free: 36.81 MB / 0.9981 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.00597/2.215, allocations: 91.12 kB / 1.26 GB, free: 36.81 MB / 0.9981 GB [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFEvalFunction.mo:718:9-721:52:writable] Error: Internal error NFEvalFunction.assignArrayElement: unimplemented case for fill(0.0, 9)[1] = 7e-07 Notification: Performance of FrontEnd: time 0.007205/2.222, allocations: 1.97 MB / 1.262 GB, free: 36.79 MB / 0.9981 GB