Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/package.mo", uses=false) Using package Buildings with version 11.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|borHol.TBorAve",fileNamePrefix="Buildings_latest_Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes") translateModel(Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|borHol.TBorAve",fileNamePrefix="Buildings_latest_Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001095/0.001094, allocations: 99.59 kB / 15.71 MB, free: 452 kB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001826/0.001826, allocations: 171.7 kB / 16.58 MB, free: 6.422 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.512/1.512, allocations: 223.2 MB / 240.6 MB, free: 5.43 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/package.mo): time 2.927/2.927, allocations: 436.7 MB / 0.7113 GB, free: 7.867 MB / 0.5606 GB Notification: Performance of FrontEnd - loaded program: time 0.0004873/0.0004874, allocations: 8.219 kB / 0.8717 GB, free: 4.742 MB / 0.7169 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.841/0.8416, allocations: 153.7 MB / 1.022 GB, free: 1.102 MB / 0.7637 GB Notification: Performance of NFInst.instantiate(Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes): time 0.1158/0.9574, allocations: 114.7 MB / 1.134 GB, free: 14.14 MB / 0.8887 GB Notification: Performance of NFInst.instExpressions: time 0.05462/1.012, allocations: 34.01 MB / 1.167 GB, free: 12.06 MB / 0.92 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.006402/1.019, allocations: 115.3 kB / 1.167 GB, free: 11.95 MB / 0.92 GB [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFEvalFunction.mo:718:9-721:52:writable] Error: Internal error NFEvalFunction.assignArrayElement: unimplemented case for fill(0.0, 9)[1] = 7e-07 Notification: Performance of FrontEnd: time 0.009164/1.028, allocations: 3.031 MB / 1.17 GB, free: 8.91 MB / 0.92 GB