Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr ThermofluidStream_OM_adaptions_ThermofluidStream.Examples.SimpleGasTurbine.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 0.4.0-OM_adaptions/package.mo", uses=false) Using package ThermofluidStream with version 0.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 0.4.0-OM_adaptions/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: translateModel(ThermofluidStream.Examples.SimpleGasTurbine,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2000,variableFilter="PI.I.y|Time|compressor.m_flow|compressor.omega|inertia.phi|turbine.m_flow|volume.M|volume.U_med",fileNamePrefix="ThermofluidStream_OM_adaptions_ThermofluidStream.Examples.SimpleGasTurbine") translateModel(ThermofluidStream.Examples.SimpleGasTurbine,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2000,variableFilter="PI.I.y|Time|compressor.m_flow|compressor.omega|inertia.phi|turbine.m_flow|volume.M|volume.U_med",fileNamePrefix="ThermofluidStream_OM_adaptions_ThermofluidStream.Examples.SimpleGasTurbine") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.007623/0.007623, allocations: 171.2 kB / 15.12 MB, free: 5.559 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.867/1.867, allocations: 205.4 MB / 221.2 MB, free: 13.82 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009822/0.0009825, allocations: 94.8 kB / 269.6 MB, free: 13.34 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 0.4.0-OM_adaptions/package.mo): time 0.9865/0.9865, allocations: 90.58 MB / 408.4 MB, free: 14.95 MB / 298.7 MB Notification: Performance of FrontEnd - loaded program: time 0.00037/0.0003702, allocations: 8 kB / 485.2 MB, free: 2.055 MB / 362.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5884/0.5888, allocations: 66.28 MB / 0.5386 GB, free: 45.61 MB / 426.7 MB Notification: Performance of NFInst.instantiate(ThermofluidStream.Examples.SimpleGasTurbine): time 0.2439/0.8328, allocations: 150.9 MB / 0.6859 GB, free: 4.754 MB / 0.4948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 0.4.0-OM_adaptions/Processes/Internal/TurboComponent/partial_dp_tau.mo:11:3-11:74:writable] Error: Medium is partial, name lookup is not allowed in partial classes. Notification: Performance of FrontEnd: time 0.0205/0.8534, allocations: 13.81 MB / 0.6994 GB, free: 6.926 MB / 0.5105 GB