Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr SiemensPower_SiemensPower.Components.Pipes.Tests.tubeTest.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo", uses=false) Using package SiemensPower with version 2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(SiemensPower.Components.Pipes.Tests.tubeTest,tolerance=1e-05,outputFormat="empty",numberOfIntervals=4000,variableFilter="",fileNamePrefix="SiemensPower_SiemensPower.Components.Pipes.Tests.tubeTest") translateModel(SiemensPower.Components.Pipes.Tests.tubeTest,tolerance=1e-05,outputFormat="empty",numberOfIntervals=4000,variableFilter="",fileNamePrefix="SiemensPower_SiemensPower.Components.Pipes.Tests.tubeTest") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008841/0.000884, allocations: 99.55 kB / 15.05 MB, free: 1.105 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001256/0.001256, allocations: 177.3 kB / 15.94 MB, free: 228 kB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.38/1.38, allocations: 205.4 MB / 222.1 MB, free: 5.652 MB / 174.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo): time 0.02764/0.02764, allocations: 5.546 MB / 275.9 MB, free: 15.77 MB / 238.1 MB Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: SiemensPower requested package Modelica of version 3.2.1. Modelica 3.2.3 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.0005242/0.0005243, allocations: 16 kB / 335.3 MB, free: 29.43 MB / 254.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.09884/0.09937, allocations: 48.87 MB / 384.1 MB, free: 12.55 MB / 286.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/Interfaces/portHeat.mo:15:3-15:40:writable] Error: Modifier '= TWall' found on outer element TWall. Notification: Performance of FrontEnd: time 0.0234/0.1228, allocations: 19.76 MB / 403.9 MB, free: 8.742 MB / 302.1 MB