Environment - simulationEnvironment: startTime=0 stopTime=0.1 tolerance=1e-06 numberOfIntervals=500 stepSize=0.0002 Regular simulation: ./Modelica_3.2.3_Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierBridge2mPulse.ThyristorBridge2mPulse_RLV -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00726703s reading init.xml | | | | | | 0.000828244s reading info.xml | | | | | | 0.00105083s [ 3.0%] pre-initialization | | | | | | 0.000201438s [ 0.6%] initialization | | | | | | 8.5219e-05s [ 0.2%] steps | | | | | | 0.00252448s [ 7.2%] solver (excl. callbacks) | | | | | | 0.00107459s [ 3.1%] creating output-file | | | | | | 0.0162993s [ 46.3%] event-handling | | | | | | 0.000215532s [ 0.6%] overhead | | | | | | 0.0137181s [ 39.0%] simulation | | | | | | 0.0351695s [100.0%] total | | | | | events | | | | | | 92 state events | | | | | | 30 time events | | | | | solver: dassl | | | | | | 2743 steps taken | | | | | | 3399 calls of functionODE | | | | | | 1294 evaluations of jacobian | | | | | | 64 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00299073s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.