Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr IDEAS_IDEAS.Buildings.Validation.Tests.n50Test2.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/package.mo", uses=false) Using package IDEAS with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(IDEAS.Buildings.Validation.Tests.n50Test2,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IDEAS_IDEAS.Buildings.Validation.Tests.n50Test2") translateModel(IDEAS.Buildings.Validation.Tests.n50Test2,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IDEAS_IDEAS.Buildings.Validation.Tests.n50Test2") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.000951/0.0009509, allocations: 100.3 kB / 15.05 MB, free: 1.105 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.0009259/0.0009261, allocations: 177.3 kB / 15.94 MB, free: 228 kB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.308/1.308, allocations: 223.2 MB / 239.9 MB, free: 5.367 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/package.mo): time 1.045/1.045, allocations: 135.2 MB / 426.2 MB, free: 14.32 MB / 350.1 MB Notification: Performance of FrontEnd - loaded program: time 0.0003501/0.0003505, allocations: 8 kB / 0.5068 GB, free: 5.277 MB / 414.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1816/0.182, allocations: 82.31 MB / 0.5872 GB, free: 3.152 MB / 494.1 MB Notification: Performance of NFInst.instantiate(IDEAS.Buildings.Validation.Tests.n50Test2): time 2.031/2.213, allocations: 0.652 GB / 1.239 GB, free: 6.91 MB / 0.8106 GB Notification: Performance of NFInst.instExpressions: time 0.3575/2.571, allocations: 236.6 MB / 1.47 GB, free: 15.22 MB / 0.9044 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.08439/2.655, allocations: 1.348 MB / 1.472 GB, free: 13.86 MB / 0.9044 GB Notification: Performance of NFTyping.typeComponents: time 0.0611/2.716, allocations: 11.74 MB / 1.483 GB, free: 2.098 MB / 0.9044 GB Notification: Performance of NFTyping.typeBindings: time 0.1365/2.853, allocations: 28.56 MB / 1.511 GB, free: 5.613 MB / 0.9356 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Buildings/Components/BaseClasses/RadiativeHeatTransfer/ZoneLwDistributionViewFactor.mo:118:5-165:11:writable] Warning: In relation zone.zoneLwDistributionViewFactor.lWall == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Buildings/Components/BaseClasses/RadiativeHeatTransfer/ZoneLwDistributionViewFactor.mo:139:11-163:17:writable] Warning: In relation zone.zoneLwDistributionViewFactor.Atot[i] == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Buildings/Components/BaseClasses/RadiativeHeatTransfer/ZoneLwDistributionViewFactor.mo:139:11-163:17:writable] Warning: In relation zone.zoneLwDistributionViewFactor.Atot[j] == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Buildings/Components/BaseClasses/RadiativeHeatTransfer/ZoneLwDistributionViewFactor.mo:118:5-165:11:writable] Warning: In relation zone1.zoneLwDistributionViewFactor.lWall == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Buildings/Components/BaseClasses/RadiativeHeatTransfer/ZoneLwDistributionViewFactor.mo:139:11-163:17:writable] Warning: In relation zone1.zoneLwDistributionViewFactor.Atot[i] == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Buildings/Components/BaseClasses/RadiativeHeatTransfer/ZoneLwDistributionViewFactor.mo:139:11-163:17:writable] Warning: In relation zone1.zoneLwDistributionViewFactor.Atot[j] == 0.0, == on Real numbers is only allowed inside functions. Notification: Performance of NFTyping.typeClassSections: time 0.1045/2.957, allocations: 26.14 MB / 1.536 GB, free: 11.75 MB / 0.9669 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFRangeIterator.mo:238:11-239:61:writable] Error: Internal error NFRangeIterator.hasNext got invalid range 1:{1, 1, 2} Notification: Performance of FrontEnd: time 0.01343/2.971, allocations: 6.226 MB / 1.542 GB, free: 5.508 MB / 0.9669 GB