Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_master_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case610.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 9.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case610,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="Buildings_master_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case610") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo): time 2.543/2.543, allocations: 287.9 MB / 302.9 MB, free: 8.223 MB / 234.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001401/0.001401, allocations: 169.2 kB / 371.4 MB, free: 10.67 MB / 298.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.969/1.969, allocations: 205.4 MB / 0.6301 GB, free: 10.4 MB / 458.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001093/0.001092, allocations: 88.59 kB / 0.7434 GB, free: 6.426 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0009722/0.0009724, allocations: 19.83 kB / 0.8662 GB, free: 141.2 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1899/0.1909, allocations: 115.3 MB / 0.9788 GB, free: 28.17 MB / 0.6198 GB Notification: Performance of NFInst.instantiate(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case610): time 0.956/1.147, allocations: 190 MB / 1.164 GB, free: 14.93 MB / 0.7136 GB Notification: Performance of NFInst.instExpressions: time 0.07536/1.222, allocations: 35.03 MB / 1.198 GB, free: 2.773 MB / 0.7292 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01607/1.238, allocations: 249.3 kB / 1.199 GB, free: 2.668 MB / 0.7292 GB Error: Internal error Instantiation of Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case610 failed with no error message. Notification: Performance of FrontEnd: time 0.009404/1.248, allocations: 2.761 MB / 1.201 GB, free: 0.9531 MB / 0.7292 GB