Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_master_Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 9.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_master_Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo): time 2.842/2.842, allocations: 287.9 MB / 302.9 MB, free: 8.348 MB / 234.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001437/0.001437, allocations: 177.1 kB / 371.4 MB, free: 10.65 MB / 298.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.973/1.973, allocations: 205.4 MB / 0.6301 GB, free: 10.35 MB / 458.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001063/0.001063, allocations: 85.2 kB / 0.7434 GB, free: 6.379 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0004908/0.0004912, allocations: 15 kB / 0.8662 GB, free: 141.4 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1633/0.1639, allocations: 115.3 MB / 0.9788 GB, free: 28.18 MB / 0.6198 GB Notification: Performance of NFInst.instantiate(Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection): time 0.7791/0.943, allocations: 174.9 MB / 1.15 GB, free: 9.914 MB / 0.698 GB Notification: Performance of NFInst.instExpressions: time 0.06008/1.003, allocations: 26.33 MB / 1.175 GB, free: 5.027 MB / 0.7136 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01336/1.017, allocations: 214.3 kB / 1.175 GB, free: 4.93 MB / 0.7136 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): roo.bouConExt.conPar.layers.nLay which gives dimensions of array: material. Array dimensions must be known at compile time. Notification: Performance of FrontEnd: time 0.008015/1.025, allocations: 1.889 MB / 1.177 GB, free: 3.617 MB / 0.7136 GB