Regular simulation: ./Buildings_master_Buildings.Obsolete.DistrictHeatingCooling.SubStations.VaporCompression.Validation.HeatingCoolingHotwaterTimeSeries_dT -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | ... loading "tab1" from "/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/Resources/Data/Obsolete/DistrictHeatingCooling/SubStations/VaporCompression/RefBldgLargeOfficeNew2004_7.1_5.0_3C_USA_CA_SAN_FRANCISCO.mos" assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | subSta.pumHea.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | subSta.pumHotWat.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | subSta.pumChi.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. assert | warning | The following assertion has been violated at time 43200.000000 | | | | subSta.heaPum.m2_flow >= 0.0 and subSta.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= subSta.heaPum.m2_flow <= 100000.0, has value: -2.77135e-18 assert | warning | The following assertion has been violated at time 147916.800000 | | | | subSta.chi.m1_flow >= 0.0 and subSta.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= subSta.chi.m1_flow <= 100000.0, has value: -1.96364e-90 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0554389s reading init.xml | | | | | | 0.00388437s reading info.xml | | | | | | 0.000140553s [ 0.0%] pre-initialization | | | | | | 0.0364485s [ 11.1%] initialization | | | | | | 2.799e-05s [ 0.0%] steps | | | | | | 0.00736531s [ 2.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00568494s [ 1.7%] event-handling | | | | | | 0.0330012s [ 10.0%] overhead | | | | | | 0.24608s [ 74.9%] simulation | | | | | | 0.328748s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1930 steps taken | | | | | | 3006 calls of functionODE | | | | | | 437 evaluations of jacobian | | | | | | 225 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0113869s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.