Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_master_Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 9.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo) Running command: translateModel(Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_master_Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo): time 2.642/2.642, allocations: 287.9 MB / 302.9 MB, free: 8.395 MB / 234.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001469/0.001469, allocations: 179 kB / 371.4 MB, free: 10.64 MB / 298.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.938/1.938, allocations: 205.4 MB / 0.6301 GB, free: 10.35 MB / 458.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001037/0.001037, allocations: 84.88 kB / 0.7434 GB, free: 6.375 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0004725/0.0004727, allocations: 9.625 kB / 0.8662 GB, free: 141.5 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1563/0.1568, allocations: 115.3 MB / 0.9787 GB, free: 28.16 MB / 0.6198 GB Notification: Performance of NFInst.instantiate(Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer): time 3.59/3.746, allocations: 0.976 GB / 1.955 GB, free: 83.22 MB / 1.12 GB Notification: Performance of NFInst.instExpressions: time 0.1971/3.944, allocations: 122.9 MB / 2.075 GB, free: 81.83 MB / 1.12 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.03288/3.976, allocations: 0.6535 MB / 2.075 GB, free: 81.83 MB / 1.12 GB Notification: Performance of NFTyping.typeComponents: time 0.04998/4.027, allocations: 8.77 MB / 2.084 GB, free: 79.77 MB / 1.12 GB Notification: Performance of NFTyping.typeBindings: time 0.09431/4.121, allocations: 22.92 MB / 2.106 GB, free: 74.43 MB / 1.12 GB Notification: Performance of NFTyping.typeClassSections: time 0.06325/4.184, allocations: 18.23 MB / 2.124 GB, free: 64.21 MB / 1.12 GB Error: Internal error Instantiation of Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer failed with no error message. Notification: Performance of FrontEnd: time 0.01964/4.204, allocations: 10.22 MB / 2.134 GB, free: 57.56 MB / 1.12 GB