Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./Buildings_latest_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.Schedule.EquipmentScheduleOutputVariable -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2023.09.23 03:35 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD stdout | info | Output Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.Schedule.EquipmentScheduleOutputVariable.equEle.y has in Modelica the unit 1. assert | warning | The following assertion has been violated at time 0.000000 | | | | duc.m_flow >= 0.0 and duc.m_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= duc.m_flow <= 100000.0, has value: -2.63739e-14 LOG_SUCCESS | info | The initialization finished successfully without homotopy method. assert | warning | The following assertion has been violated at time 25200.000000 | | | | if noEvent(time > assEqu.t0) then noEvent(abs(equEle.y - assEqu.u2) < assEqu.threShold) else true assert | error | EnergyPlus did not synchronize the output variable correctly | | | | time = 25200 | | | | u1 = 0 | | | | u2 = 500 | | | | abs(u1-u2) = 500 | | | | threShold = 1e-06 Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.28sec EnergyPlus Completed Successfully.