startTime=0 stopTime=3.1536e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=12614.4 Regular simulation: ./Buildings_8.0.0_Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Resources/Data/Obsolete/DistrictHeatingCooling/SubStations/VaporCompression/RefBldgLargeOfficeNew2004_7.1_5.0_3C_USA_CA_SAN_FRANCISCO.mos" stdout | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Resources/Data/Obsolete/DistrictHeatingCooling/SubStations/VaporCompression/RefBldgStand-aloneRetailNew2004_7.1_5.0_3C_USA_CA_SAN_FRANCISCO.mos" stdout | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Resources/Data/Obsolete/DistrictHeatingCooling/SubStations/VaporCompression/RefBldgMidriseApartmentNew2004_7.1_5.0_3C_USA_CA_SAN_FRANCISCO.mos" assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff1.pumHea.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff1.pumHotWat.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff1.pumChi.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | ret1.pumHea.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | ret1.pumHotWat.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | ret1.pumChi.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff2.pumHea.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff2.pumHotWat.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff2.pumChi.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | apa1.pumHea.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | apa1.pumHotWat.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | apa1.pumChi.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff3.pumHea.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff3.pumHotWat.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff3.pumChi.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff4.pumHea.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff4.pumHotWat.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff4.pumChi.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | apa2.pumHea.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | apa2.pumHotWat.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | apa2.pumChi.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | ret2.pumHea.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | ret2.pumHotWat.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | ret2.pumChi.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. assert | warning | The following assertion has been violated at time 50457.600000 | | | | larOff1.heaPum.m2_flow >= 0.0 and larOff1.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff1.heaPum.m2_flow <= 100000.0, has value: -1.81685e-269 assert | warning | The following assertion has been violated at time 50457.600000 | | | | larOff2.heaPum.m2_flow >= 0.0 and larOff2.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff2.heaPum.m2_flow <= 100000.0, has value: -1.81685e-269 assert | warning | The following assertion has been violated at time 50457.600000 | | | | larOff3.heaPum.m2_flow >= 0.0 and larOff3.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff3.heaPum.m2_flow <= 100000.0, has value: -1.81685e-269 assert | warning | The following assertion has been violated at time 50457.600000 | | | | larOff4.heaPum.m2_flow >= 0.0 and larOff4.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff4.heaPum.m2_flow <= 100000.0, has value: -1.81685e-269 assert | warning | The following assertion has been violated at time 63072.000000 | | | | ret1.chi.m1_flow >= 0.0 and ret1.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= ret1.chi.m1_flow <= 100000.0, has value: -8.39735e-140 assert | warning | The following assertion has been violated at time 63072.000000 | | | | ret2.chi.m1_flow >= 0.0 and ret2.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= ret2.chi.m1_flow <= 100000.0, has value: -8.39735e-140 assert | warning | The following assertion has been violated at time 81993.600000 | | | | ret1.heaPum.m2_flow >= 0.0 and ret1.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= ret1.heaPum.m2_flow <= 100000.0, has value: -2.24783e-63 assert | warning | The following assertion has been violated at time 81993.600000 | | | | ret2.heaPum.m2_flow >= 0.0 and ret2.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= ret2.heaPum.m2_flow <= 100000.0, has value: -2.24783e-63 assert | warning | The following assertion has been violated at time 157680.000000 | | | | larOff1.chi.m1_flow >= 0.0 and larOff1.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff1.chi.m1_flow <= 100000.0, has value: -2.47033e-323 assert | warning | The following assertion has been violated at time 157680.000000 | | | | larOff3.chi.m1_flow >= 0.0 and larOff3.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff3.chi.m1_flow <= 100000.0, has value: -2.47033e-323 assert | warning | The following assertion has been violated at time 157680.000000 | | | | larOff4.chi.m1_flow >= 0.0 and larOff4.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff4.chi.m1_flow <= 100000.0, has value: -2.47033e-323 assert | warning | The following assertion has been violated at time 227059.200000 | | | | apa1.heaPum.m2_flow >= 0.0 and apa1.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= apa1.heaPum.m2_flow <= 100000.0, has value: -3.56851e-22 assert | warning | The following assertion has been violated at time 227059.200000 | | | | apa2.heaPum.m2_flow >= 0.0 and apa2.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= apa2.heaPum.m2_flow <= 100000.0, has value: -3.56851e-22 assert | warning | The following assertion has been violated at time 1128988.800000 | | | | apa1.chi.m1_flow >= 0.0 and apa1.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= apa1.chi.m1_flow <= 100000.0, has value: -4.17619e-53 assert | warning | The following assertion has been violated at time 1128988.800000 | | | | apa2.chi.m1_flow >= 0.0 and apa2.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= apa2.chi.m1_flow <= 100000.0, has value: -4.17619e-53 assert | warning | The following assertion has been violated at time 7600176.000000 | | | | noEvent(abs(apa1.heaPum.eva.Q_flow) < 200.0 * apa1.heaPum.eva.vol.steBal.cp_default * max(0.001 * apa1.heaPum.eva.vol.steBal.m_flow_small, abs(apa1.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.apa1.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 0.147611 W and the mass flow rate equals -2.28511e-08 kg/s, | | | | which results in a temperature difference 390.674 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 9303120.000000 | | | | noEvent(abs(larOff1.heaPum.eva.Q_flow) < 200.0 * larOff1.heaPum.eva.vol.steBal.cp_default * max(0.001 * larOff1.heaPum.eva.vol.steBal.m_flow_small, abs(larOff1.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.larOff1.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 4.73414 W and the mass flow rate equals -1.07392e-06 kg/s, | | | | which results in a temperature difference 310.055 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 9561715.200000 | | | | noEvent(abs(ret1.heaPum.eva.Q_flow) < 200.0 * ret1.heaPum.eva.vol.steBal.cp_default * max(0.001 * ret1.heaPum.eva.vol.steBal.m_flow_small, abs(ret1.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.ret1.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 1.07544 W and the mass flow rate equals -1.67501e-07 kg/s, | | | | which results in a temperature difference 381.882 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 12791001.600000 | | | | noEvent(abs(apa1.heaPum.eva.Q_flow) < 200.0 * apa1.heaPum.eva.vol.steBal.cp_default * max(0.001 * apa1.heaPum.eva.vol.steBal.m_flow_small, abs(apa1.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.apa1.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 0.154325 W and the mass flow rate equals -1.99492e-08 kg/s, | | | | which results in a temperature difference 408.445 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 18158428.800000 | | | | noEvent(abs(ret1.heaPum.eva.Q_flow) < 200.0 * ret1.heaPum.eva.vol.steBal.cp_default * max(0.001 * ret1.heaPum.eva.vol.steBal.m_flow_small, abs(ret1.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.ret1.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 1.15 W and the mass flow rate equals -1.7218e-07 kg/s, | | | | which results in a temperature difference 408.359 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 24080889.600000 | | | | noEvent(abs(larOff1.heaPum.eva.Q_flow) < 200.0 * larOff1.heaPum.eva.vol.steBal.cp_default * max(0.001 * larOff1.heaPum.eva.vol.steBal.m_flow_small, abs(larOff1.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.larOff1.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 3.25386 W and the mass flow rate equals -2.36512e-06 kg/s, | | | | which results in a temperature difference 213.107 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 25922592.000000 | | | | noEvent(abs(apa1.heaPum.eva.Q_flow) < 200.0 * apa1.heaPum.eva.vol.steBal.cp_default * max(0.001 * apa1.heaPum.eva.vol.steBal.m_flow_small, abs(apa1.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.apa1.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 0.153064 W and the mass flow rate equals -2.61611e-08 kg/s, | | | | which results in a temperature difference 405.108 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 26931744.000000 | | | | noEvent(abs(ret1.heaPum.eva.Q_flow) < 200.0 * ret1.heaPum.eva.vol.steBal.cp_default * max(0.001 * ret1.heaPum.eva.vol.steBal.m_flow_small, abs(ret1.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.ret1.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 0.981694 W and the mass flow rate equals -2.35954e-07 kg/s, | | | | which results in a temperature difference 348.593 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 27890438.400000 | | | | noEvent(abs(ret1.heaPum.eva.Q_flow) < 200.0 * ret1.heaPum.eva.vol.steBal.cp_default * max(0.001 * ret1.heaPum.eva.vol.steBal.m_flow_small, abs(ret1.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.ret1.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 0.642737 W and the mass flow rate equals -2.42646e-07 kg/s, | | | | which results in a temperature difference 228.231 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 27896745.600000 | | | | noEvent(abs(apa1.heaPum.eva.Q_flow) < 200.0 * apa1.heaPum.eva.vol.steBal.cp_default * max(0.001 * apa1.heaPum.eva.vol.steBal.m_flow_small, abs(apa1.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.apa1.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 0.151722 W and the mass flow rate equals -2.16711e-08 kg/s, | | | | which results in a temperature difference 401.556 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 27896745.600000 | | | | noEvent(abs(apa1.heaPum.eva.Q_flow) < 200.0 * apa1.heaPum.eva.vol.steBal.cp_default * max(0.001 * apa1.heaPum.eva.vol.steBal.m_flow_small, abs(apa1.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.apa1.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 0.151722 W and the mass flow rate equals -2.16711e-08 kg/s, | | | | which results in a temperature difference 401.556 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 27896745.600000 | | | | noEvent(abs(apa1.heaPum.eva.Q_flow) < 200.0 * apa1.heaPum.eva.vol.steBal.cp_default * max(0.001 * apa1.heaPum.eva.vol.steBal.m_flow_small, abs(apa1.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.apa1.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 0.151722 W and the mass flow rate equals -2.16711e-08 kg/s, | | | | which results in a temperature difference 401.556 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 27896745.600000 | | | | noEvent(abs(apa1.heaPum.eva.Q_flow) < 200.0 * apa1.heaPum.eva.vol.steBal.cp_default * max(0.001 * apa1.heaPum.eva.vol.steBal.m_flow_small, abs(apa1.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.apa1.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 0.151722 W and the mass flow rate equals -2.16711e-08 kg/s, | | | | which results in a temperature difference 401.556 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 30949430.400000 | | | | noEvent(abs(larOff1.heaPum.eva.Q_flow) < 200.0 * larOff1.heaPum.eva.vol.steBal.cp_default * max(0.001 * larOff1.heaPum.eva.vol.steBal.m_flow_small, abs(larOff1.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.larOff1.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 6.07973 W and the mass flow rate equals -8.62131e-07 kg/s, | | | | which results in a temperature difference 398.183 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 30999888.000000 | | | | noEvent(abs(larOff1.heaPum.eva.Q_flow) < 200.0 * larOff1.heaPum.eva.vol.steBal.cp_default * max(0.001 * larOff1.heaPum.eva.vol.steBal.m_flow_small, abs(larOff1.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.larOff1.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 3.07928 W and the mass flow rate equals -2.32292e-06 kg/s, | | | | which results in a temperature difference 201.673 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.382613s reading init.xml | | | | | | 0.034464s reading info.xml | | | | | | 0.000429142s [ 0.0%] pre-initialization | | | | | | 0.0503249s [ 0.6%] initialization | | | | | | 0.00172657s [ 0.0%] steps | | | | | | 0.159561s [ 1.8%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.04047s [ 0.4%] event-handling | | | | | | 0.256621s [ 2.8%] overhead | | | | | | 8.52265s [ 94.4%] simulation | | | | | | 9.03178s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 678 steps taken | | | | | | 1066 calls of functionODE | | | | | | 135 evaluations of jacobian | | | | | | 58 error test failures | | | | | | 0 convergence test failures | | | | | | 0.446088s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.