Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.RoomCapacityMultiplier.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.RoomCapacityMultiplier,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.RoomCapacityMultiplier") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.298/2.298, allocations: 251.1 MB / 266.1 MB, free: 11.63 MB / 218.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.002112/0.002112, allocations: 178.5 kB / 325.6 MB, free: 2.824 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.506/2.506, allocations: 205.4 MB / 0.5766 GB, free: 20.73 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001182/0.001182, allocations: 89.95 kB / 0.6811 GB, free: 13.61 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0007015/0.0007016, allocations: 15.88 kB / 0.7951 GB, free: 135.6 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3227/0.3234, allocations: 106.3 MB / 0.8989 GB, free: 65.5 MB / 0.6042 GB Notification: Performance of NFInst.instantiate(Buildings.ThermalZones.Detailed.Validation.RoomCapacityMultiplier): time 1.067/1.391, allocations: 228 MB / 1.122 GB, free: 5.559 MB / 0.698 GB Notification: Performance of NFInst.instExpressions: time 0.1104/1.501, allocations: 43.48 MB / 1.164 GB, free: 4.027 MB / 0.698 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.03205/1.533, allocations: 403.6 kB / 1.164 GB, free: 3.855 MB / 0.698 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): roo1.bouConExt.conPar.layers.nLay which gives dimensions of array: material. Array dimensions must be known at compile time. Notification: Performance of FrontEnd: time 0.009707/1.543, allocations: 1.885 MB / 1.166 GB, free: 3.281 MB / 0.698 GB