Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection.conf.json Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection") Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo): time 0.009824/0.009828, allocations: 108.7 kB / 15.06 MB, free: 5.562 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo): time 0.00188/0.001881, allocations: 180.1 kB / 15.95 MB, free: 5.523 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo): time 2.012/2.012, allocations: 194.6 MB / 211.3 MB, free: 11.29 MB / 170.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo): time 2.314/2.314, allocations: 236.2 MB / 492.6 MB, free: 11.34 MB / 394.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0007946/0.0007951, allocations: 12 kB / 0.5869 GB, free: 2.176 MB / 490.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6364/0.6373, allocations: 98.7 MB / 0.6833 GB, free: 16.78 MB / 0.5261 GB Notification: Performance of NFInst.instantiate(Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection): time 0.2601/0.8974, allocations: 174.7 MB / 0.854 GB, free: 15.28 MB / 0.6824 GB Notification: Performance of NFInst.instExpressions: time 0.05873/0.9562, allocations: 26.35 MB / 0.8797 GB, free: 4.863 MB / 0.698 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01233/0.9685, allocations: 206.6 kB / 0.8799 GB, free: 4.66 MB / 0.698 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): roo.bouConExt.conPar.layers.nLay which gives dimensions of array: material. Array dimensions must be known at compile time. Notification: Performance of FrontEnd: time 0.007341/0.9759, allocations: 1.883 MB / 0.8817 GB, free: 2.77 MB / 0.698 GB