Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes.conf.json Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Running command: translateModel(Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes") Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo): time 0.009003/0.009003, allocations: 106.9 kB / 15.06 MB, free: 5.562 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo): time 0.001106/0.001105, allocations: 181.4 kB / 15.95 MB, free: 5.523 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo): time 2.114/2.114, allocations: 194.6 MB / 211.3 MB, free: 11 MB / 170.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo): time 2.1/2.1, allocations: 236.1 MB / 492.6 MB, free: 11.36 MB / 394.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0004678/0.0004678, allocations: 12 kB / 0.5869 GB, free: 2.172 MB / 490.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5261/0.5266, allocations: 98.72 MB / 0.6833 GB, free: 16.8 MB / 0.5261 GB Notification: Performance of NFInst.instantiate(Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes): time 0.1453/0.672, allocations: 102.4 MB / 0.7834 GB, free: 7.785 MB / 0.6042 GB Notification: Performance of NFInst.instExpressions: time 0.05962/0.7316, allocations: 31.46 MB / 0.8141 GB, free: 8.273 MB / 0.6355 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.005282/0.737, allocations: 107.3 kB / 0.8142 GB, free: 8.168 MB / 0.6355 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFCeval.mo:1125:9-1125:67:writable] Error: Internal error NFCeval.evalBinaryPow failed to evaluate ‘borFieDat.conDat.hBor ^ 2.0‘ Notification: Performance of FrontEnd: time 0.002084/0.7391, allocations: 0.4983 MB / 0.8147 GB, free: 7.668 MB / 0.6355 GB