Regular simulation: ./Buildings_6.0.0_Buildings.Experimental.DistrictHeatingCooling.SubStations.VaporCompression.Validation.HeatingCoolingHotwaterTimeSeries_dT -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | ... loading "tab1" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Resources/Data/Experimental/DistrictHeatingCooling/SubStations/VaporCompression/RefBldgLargeOfficeNew2004_7.1_5.0_3C_USA_CA_SAN_FRANCISCO.mos" stdout | info | ... loading "tab1" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Resources/weatherdata/USA_CA_San.Francisco.Intl.AP.724940_TMY3.mos" assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | subSta.pumHea.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | subSta.pumHotWat.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | subSta.pumChi.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. assert | warning | The following assertion has been violated at time 14400.000000 | | | | weaDat.totSkyCov_in_internal >= 0.0 and weaDat.totSkyCov_in_internal <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaDat.totSkyCov_in_internal <= 1.0, has value: -2.48353e-13 assert | warning | The following assertion has been violated at time 14400.000000 | | | | weaDat.opaSkyCov_in_internal >= 0.0 and weaDat.opaSkyCov_in_internal <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaDat.opaSkyCov_in_internal <= 1.0, has value: -2.48353e-13 assert | warning | The following assertion has been violated at time 43372.800000 | | | | subSta.heaPum.m2_flow >= 0.0 and subSta.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= subSta.heaPum.m2_flow <= 100000.0, has value: -2.00732e-69 assert | warning | The following assertion has been violated at time 514800.000001 | | | | weaDat.weaBus.nOpa >= 0.0 and weaDat.weaBus.nOpa <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaDat.weaBus.nOpa <= 1.0, has value: 1 assert | warning | The following assertion has been violated at time 514800.000001 | | | | weaDat.weaBus.nTot >= 0.0 and weaDat.weaBus.nTot <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaDat.weaBus.nTot <= 1.0, has value: 1 assert | warning | The following assertion has been violated at time 514800.000001 | | | | weaDat.TBlaSkyCom.nOpa10 >= 0.0 and weaDat.TBlaSkyCom.nOpa10 <= 10.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaDat.TBlaSkyCom.nOpa10 <= 10.0, has value: 10 assert | warning | The following assertion has been violated at time 529200.000001 | | | | weaDat.relHum_in_internal >= 0.0 and weaDat.relHum_in_internal <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaDat.relHum_in_internal <= 1.0, has value: 1 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0402001s reading init.xml | | | | | | 0.00392532s reading info.xml | | | | | | 0.000133855s [ 0.0%] pre-initialization | | | | | | 0.0392595s [ 6.7%] initialization | | | | | | 3.1693e-05s [ 0.0%] steps | | | | | | 0.0186703s [ 3.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0305671s [ 5.2%] event-handling | | | | | | 0.0361155s [ 6.2%] overhead | | | | | | 0.459169s [ 78.6%] simulation | | | | | | 0.583947s [100.0%] total | | | | | events | | | | | | 239 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 6311 steps taken | | | | | | 8084 calls of functionODE | | | | | | 3832 evaluations of jacobian | | | | | | 267 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0996443s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.