Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_3.0.0_Buildings.Fluid.HeatExchangers.RadiantSlabs.Examples.StepResponseEpsilonNTU.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo", uses=false) Using package Buildings with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica_StateGraph2 with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo) Running command: translateModel(Buildings.Fluid.HeatExchangers.RadiantSlabs.Examples.StepResponseEpsilonNTU,tolerance=1e-05,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.Fluid.HeatExchangers.RadiantSlabs.Examples.StepResponseEpsilonNTU") translateModel(Buildings.Fluid.HeatExchangers.RadiantSlabs.Examples.StepResponseEpsilonNTU,tolerance=1e-05,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.Fluid.HeatExchangers.RadiantSlabs.Examples.StepResponseEpsilonNTU") [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:257:38-257:110:writable] Warning: The file was not encoded in UTF-8: "

An important practical aspect of state machines is the abilit...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:761:36-761:108:writable] Warning: The file was not encoded in UTF-8: "

The Modelica_StateGraph2 library is described in detail in (O...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:1435:36-1435:108:writable] Warning: The file was not encoded in UTF-8: "

Main Authors:
SCode: time 0.1879/0.1886, allocations: 82.22 MB / 0.5934 GB, free: 5.98 MB / 446.1 MB Notification: Performance of NFInst.instantiate(Buildings.Fluid.HeatExchangers.RadiantSlabs.Examples.StepResponseEpsilonNTU): time 0.02846/0.2171, allocations: 26.23 MB / 0.619 GB, free: 11.67 MB / 478.1 MB Notification: Performance of NFInst.instExpressions: time 0.01721/0.2344, allocations: 9.759 MB / 0.6285 GB, free: 1.895 MB / 478.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.002445/0.2369, allocations: 47.69 kB / 0.6286 GB, free: 1.848 MB / 478.1 MB Notification: Performance of NFTyping.typeComponents: time 0.003745/0.2406, allocations: 0.996 MB / 0.6295 GB, free: 0.8477 MB / 478.1 MB Notification: Performance of NFTyping.typeBindings: time 0.005897/0.2466, allocations: 1.495 MB / 0.631 GB, free: 15.35 MB / 494.1 MB Notification: Performance of NFTyping.typeClassSections: time 0.004799/0.2514, allocations: 1.323 MB / 0.6323 GB, free: 14.05 MB / 494.1 MB Notification: Performance of NFFlatten.flatten: time 0.01213/0.2635, allocations: 8.726 MB / 0.6408 GB, free: 5.309 MB / 494.1 MB Notification: Performance of NFFlatten.resolveConnections: time 0.007161/0.2707, allocations: 4.449 MB / 0.6452 GB, free: 0.8047 MB / 494.1 MB Notification: Performance of NFEvalConstants.evaluate: time 0.009122/0.2799, allocations: 3.594 MB / 0.6487 GB, free: 13.2 MB / 0.4981 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/HeatTransfer/Conduction/BaseClasses/temperature_u.mo:9:41-9:55:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/HeatTransfer/Conduction/BaseClasses/temperature_u.mo:9:3-10:46:writable] Error: Non-array modification ‘"kg.K2/J"‘ for array component ‘unit‘, possibly due to missing ‘each‘. Notification: Performance of FrontEnd: time 0.006183/0.2861, allocations: 2.461 MB / 0.6511 GB, free: 10.73 MB / 0.4981 GB