Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0004 Regular simulation: ./AixLib_latest_AixLib.Fluid.Movers.Compressors.Examples.RotaryCompressorPressureLosses -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | error | Fluid state is too close to the two-phase region (p=428632[Pa], T=283.15[K]. Pressure and temperature can not be used to determine properties in two-phase region. assert | error | Failed to solve the initialization problem with global homotopy with equidistant step size. assert | debug | Unable to solve initialization problem. assert | info | simulation terminated by an assertion at initialization