Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0004 Regular simulation: ./AixLib_AixLib.Fluid.Actuators.Valves.Examples.TwoWayValveTable -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00274262s reading init.xml | | | | | | 0.000217799s reading info.xml | | | | | | 8.5391e-05s [ 1.5%] pre-initialization | | | | | | 0.00011752s [ 2.1%] initialization | | | | | | 4.41e-07s [ 0.0%] steps | | | | | | 5.249e-05s [ 0.9%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 3.2971e-05s [ 0.6%] event-handling | | | | | | 0.00212938s [ 38.5%] overhead | | | | | | 0.00311721s [ 56.3%] simulation | | | | | | 0.0055354s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 5000 steps taken | | | | | | 5000 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.