OMSimulator -r=Modelica_3.2.3_Modelica.Electrical.Digital.Examples.DFFREGSRH_res.mat --tempDir=temp_Modelica_3_2_3_Modelica_Electrical_Digital_Examples_DFFREGSRH_fmu --startTime=0 --stopTime=15 --timeout=50 --tolerance=1e-06 Modelica_3_2_3_Modelica_Electrical_Digital_Examples_DFFREGSRH.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_Modelica_3_2_3_Modelica_Electrical_Digital_Examples_DFFREGSRH_fmu" info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Modelica_3.2.3_Modelica.Electrical.Digital.Examples.DFFREGSRH/temp_Modelica_3_2_3_Modelica_Electrical_Digital_Examples_DFFREGSRH_fmu" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Modelica_3.2.3_Modelica.Electrical.Digital.Examples.DFFREGSRH" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Modelica_3.2.3_Modelica.Electrical.Digital.Examples.DFFREGSRH/temp_Modelica_3_2_3_Modelica_Electrical_Digital_Examples_DFFREGSRH_fmu/model-g9ugwpww" info: model doesn't contain any continuous state warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Electrical/Digital.mo:2239: The following assertion has been violated at time 0.000000 dFFREGSRH.delay.inertialDelaySensitive[1].x >= Modelica.Electrical.Digital.Interfaces.Logic.'U' and dFFREGSRH.delay.inertialDelaySensitive[1].x <= Modelica.Electrical.Digital.Interfaces.Logic.'-' assert | warning | Variable violating min/max constraint: Modelica.Electrical.Digital.Interfaces.Logic.'U' <= dFFREGSRH.delay.inertialDelaySensitive[1].x <= Modelica.Electrical.Digital.Interfaces.Logic.'-', has value: 0 warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Electrical/Digital.mo:2239: The following assertion has been violated at time 0.000000 dFFREGSRH.delay.inertialDelaySensitive[2].x >= Modelica.Electrical.Digital.Interfaces.Logic.'U' and dFFREGSRH.delay.inertialDelaySensitive[2].x <= Modelica.Electrical.Digital.Interfaces.Logic.'-' assert | warning | Variable violating min/max constraint: Modelica.Electrical.Digital.Interfaces.Logic.'U' <= dFFREGSRH.delay.inertialDelaySensitive[2].x <= Modelica.Electrical.Digital.Interfaces.Logic.'-', has value: 0 warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Electrical/Digital.mo:4961: The following assertion has been violated at time 0.000000 dFFREGSRH.dFFSR.dataOut[1] >= Modelica.Electrical.Digital.Interfaces.Logic.'U' and dFFREGSRH.dFFSR.dataOut[1] <= Modelica.Electrical.Digital.Interfaces.Logic.'-' assert | warning | Variable violating min/max constraint: Modelica.Electrical.Digital.Interfaces.Logic.'U' <= dFFREGSRH.dFFSR.dataOut[1] <= Modelica.Electrical.Digital.Interfaces.Logic.'-', has value: 0 warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Electrical/Digital.mo:4961: The following assertion has been violated at time 0.000000 dFFREGSRH.dFFSR.dataOut[2] >= Modelica.Electrical.Digital.Interfaces.Logic.'U' and dFFREGSRH.dFFSR.dataOut[2] <= Modelica.Electrical.Digital.Interfaces.Logic.'-' assert | warning | Variable violating min/max constraint: Modelica.Electrical.Digital.Interfaces.Logic.'U' <= dFFREGSRH.dFFSR.dataOut[2] <= Modelica.Electrical.Digital.Interfaces.Logic.'-', has value: 0 warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Electrical/Digital.mo:4981: The following assertion has been violated at time 0.000000 dFFREGSRH.dFFSR.nextstate[1] >= Modelica.Electrical.Digital.Interfaces.Logic.'U' and dFFREGSRH.dFFSR.nextstate[1] <= Modelica.Electrical.Digital.Interfaces.Logic.'-' assert | warning | Variable violating min/max constraint: Modelica.Electrical.Digital.Interfaces.Logic.'U' <= dFFREGSRH.dFFSR.nextstate[1] <= Modelica.Electrical.Digital.Interfaces.Logic.'-', has value: 0 warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Electrical/Digital.mo:4981: The following assertion has been violated at time 0.000000 dFFREGSRH.dFFSR.nextstate[2] >= Modelica.Electrical.Digital.Interfaces.Logic.'U' and dFFREGSRH.dFFSR.nextstate[2] <= Modelica.Electrical.Digital.Interfaces.Logic.'-' assert | warning | Variable violating min/max constraint: Modelica.Electrical.Digital.Interfaces.Logic.'U' <= dFFREGSRH.dFFSR.nextstate[2] <= Modelica.Electrical.Digital.Interfaces.Logic.'-', has value: 0 warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Electrical/Digital.mo:4982: The following assertion has been violated at time 0.000000 dFFREGSRH.dFFSR.next_assign_val[1] >= Modelica.Electrical.Digital.Interfaces.Logic.'U' and dFFREGSRH.dFFSR.next_assign_val[1] <= Modelica.Electrical.Digital.Interfaces.Logic.'-' assert | warning | Variable violating min/max constraint: Modelica.Electrical.Digital.Interfaces.Logic.'U' <= dFFREGSRH.dFFSR.next_assign_val[1] <= Modelica.Electrical.Digital.Interfaces.Logic.'-', has value: 0 warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Electrical/Digital.mo:4982: The following assertion has been violated at time 0.000000 dFFREGSRH.dFFSR.next_assign_val[2] >= Modelica.Electrical.Digital.Interfaces.Logic.'U' and dFFREGSRH.dFFSR.next_assign_val[2] <= Modelica.Electrical.Digital.Interfaces.Logic.'-' assert | warning | Variable violating min/max constraint: Modelica.Electrical.Digital.Interfaces.Logic.'U' <= dFFREGSRH.dFFSR.next_assign_val[2] <= Modelica.Electrical.Digital.Interfaces.Logic.'-', has value: 0 info: No result file will be created info: 8 warnings info: 0 errors