Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr IndustrialControlSystems_IndustrialControlSystems.Applications.ControlProblems.ATProcessControl.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/package.mo", uses=false) Using package IndustrialControlSystems with version 1.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(IndustrialControlSystems.Applications.ControlProblems.ATProcessControl,fileNamePrefix="IndustrialControlSystems_IndustrialControlSystems_Applications_ControlProblems_ATProcessControl",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(IndustrialControlSystems.Applications.ControlProblems.ATProcessControl,fileNamePrefix="IndustrialControlSystems_IndustrialControlSystems_Applications_ControlProblems_ATProcessControl",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001126/0.001127, allocations: 99.55 kB / 15.05 MB, free: 1.105 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.0009569/0.0009569, allocations: 177.3 kB / 15.94 MB, free: 228 kB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.633/1.633, allocations: 205.4 MB / 222.1 MB, free: 5.523 MB / 174.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/package.mo): time 0.0584/0.0584, allocations: 10.74 MB / 281.1 MB, free: 10.43 MB / 238.1 MB Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.0005029/0.0005031, allocations: 20 kB / 341.7 MB, free: 23.76 MB / 254.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1033/0.1038, allocations: 50 MB / 391.7 MB, free: 5.684 MB / 286.1 MB Notification: Performance of NFInst.instantiate(IndustrialControlSystems.Applications.ControlProblems.ATProcessControl): time 0.005532/0.1094, allocations: 4.55 MB / 396.2 MB, free: 1.105 MB / 286.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/Controllers/AutoTuning/ATPIrelayNCmixedMode.mo:91:8-91:29:writable] Error: Operator reinit may only be used in the body of a when equation. Notification: Performance of FrontEnd: time 0.001171/0.1106, allocations: 0.5697 MB / 396.8 MB, free: 0.5352 MB / 286.1 MB