OMSimulator --tempDir=temp_IDEAS_dev_IDEAS_Fluid_HeatPumps_Examples_HeatPump_WaterWaterTSet_fmu --startTime=0 --stopTime=1000 --timeout=50 --tolerance=1e-06 IDEAS_dev_IDEAS_Fluid_HeatPumps_Examples_HeatPump_WaterWaterTSet.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_IDEAS_dev_IDEAS_Fluid_HeatPumps_Examples_HeatPump_WaterWaterTSet_fmu" info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_dev_IDEAS.Fluid.HeatPumps.Examples.HeatPump_WaterWaterTSet/temp_IDEAS_dev_IDEAS_Fluid_HeatPumps_Examples_HeatPump_WaterWaterTSet_fmu" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_dev_IDEAS.Fluid.HeatPumps.Examples.HeatPump_WaterWaterTSet" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_dev_IDEAS.Fluid.HeatPumps.Examples.HeatPump_WaterWaterTSet/temp_IDEAS_dev_IDEAS_Fluid_HeatPumps_Examples_HeatPump_WaterWaterTSet_fmu/model-52n8bmk5" warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348: The following assertion has been violated during initialization at time 0.000000 pump1.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348: The following assertion has been violated during initialization at time 0.000000 pump.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. info: maximum step size for 'model.root': 0.100000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.fmu.heatPump.copTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.fmu.heatPump.copTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.fmu.heatPump.powerTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.fmu.heatPump.powerTable.tableName will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 5266 NumRhsEvals = 5611 NumLinSolvSetups = 472 NumNonlinSolvIters = 5610 NumNonlinSolvConvFails = 0 NumErrTestFails = 92 info: 2 warnings info: 0 errors