Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case980FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case980FF,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases9xx_Case980FF",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case980FF,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases9xx_Case980FF",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001226/0.001227, allocations: 99.7 kB / 15.05 MB, free: 1.105 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001588/0.001588, allocations: 177.3 kB / 15.94 MB, free: 228 kB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.537/1.537, allocations: 223.2 MB / 239.9 MB, free: 5.363 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 3.021/3.021, allocations: 409.2 MB / 0.6838 GB, free: 0.9609 MB / 0.5294 GB Notification: Performance of FrontEnd - loaded program: time 0.0003776/0.0003777, allocations: 8 kB / 0.8375 GB, free: 6.559 MB / 0.6856 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.9273/0.9277, allocations: 146.8 MB / 0.9809 GB, free: 6.297 MB / 0.7325 GB Notification: Performance of NFInst.instantiate(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case980FF): time 0.2569/1.185, allocations: 193.8 MB / 1.17 GB, free: 4.016 MB / 0.92 GB Notification: Performance of NFInst.instExpressions: time 0.06812/1.253, allocations: 36.26 MB / 1.206 GB, free: 15.68 MB / 0.9669 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01634/1.269, allocations: 234.4 kB / 1.206 GB, free: 15.45 MB / 0.9669 GB Error: Internal error Instantiation of Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case980FF failed with no error message. Notification: Performance of FrontEnd: time 0.01001/1.279, allocations: 3.312 MB / 1.209 GB, free: 12.13 MB / 0.9669 GB