Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case600FF",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case600FF",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001106/0.001106, allocations: 99.86 kB / 15.05 MB, free: 1.105 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001277/0.001277, allocations: 177.3 kB / 15.94 MB, free: 228 kB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.533/1.533, allocations: 223.2 MB / 239.9 MB, free: 5.348 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 2.771/2.771, allocations: 409.2 MB / 0.6838 GB, free: 1.043 MB / 0.5294 GB Notification: Performance of FrontEnd - loaded program: time 0.0003422/0.0003423, allocations: 8 kB / 0.8375 GB, free: 6.559 MB / 0.6856 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.8901/0.8904, allocations: 146.8 MB / 0.9809 GB, free: 6.289 MB / 0.7325 GB Notification: Performance of NFInst.instantiate(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF): time 0.2406/1.131, allocations: 193.1 MB / 1.169 GB, free: 4.746 MB / 0.92 GB Notification: Performance of NFInst.instExpressions: time 0.07471/1.206, allocations: 35.38 MB / 1.204 GB, free: 1.293 MB / 0.9513 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01685/1.223, allocations: 234.4 kB / 1.204 GB, free: 1.062 MB / 0.9513 GB Error: Internal error Instantiation of Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF failed with no error message. Notification: Performance of FrontEnd: time 0.009236/1.232, allocations: 2.743 MB / 1.207 GB, free: 14.31 MB / 0.9669 GB