Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case600",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case600",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.000991/0.0009909, allocations: 100 kB / 15.05 MB, free: 1.105 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001023/0.001023, allocations: 177.3 kB / 15.94 MB, free: 228 kB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.452/1.452, allocations: 223.2 MB / 239.9 MB, free: 5.344 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 2.671/2.671, allocations: 409.2 MB / 0.6838 GB, free: 0.9727 MB / 0.5294 GB Notification: Performance of FrontEnd - loaded program: time 0.0003893/0.0003893, allocations: 12 kB / 0.8375 GB, free: 6.57 MB / 0.6856 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.8768/0.8772, allocations: 146.8 MB / 0.9809 GB, free: 6.324 MB / 0.7325 GB Notification: Performance of NFInst.instantiate(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600): time 0.2423/1.12, allocations: 195.1 MB / 1.171 GB, free: 2.766 MB / 0.92 GB Notification: Performance of NFInst.instExpressions: time 0.07191/1.192, allocations: 36.39 MB / 1.207 GB, free: 14.3 MB / 0.9669 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01634/1.208, allocations: 246.4 kB / 1.207 GB, free: 14.06 MB / 0.9669 GB Error: Internal error Instantiation of Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600 failed with no error message. Notification: Performance of FrontEnd: time 0.009218/1.217, allocations: 2.751 MB / 1.21 GB, free: 11.3 MB / 0.9669 GB