Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case680FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case680FF,fileNamePrefix="Buildings_9_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case680FF",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case680FF,fileNamePrefix="Buildings_9_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case680FF",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009689/0.000973, allocations: 99.86 kB / 15.05 MB, free: 1.105 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.0009844/0.0009845, allocations: 177.3 kB / 15.95 MB, free: 216 kB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.513/1.513, allocations: 223.2 MB / 239.9 MB, free: 5.453 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.523/2.523, allocations: 390.3 MB / 0.6653 GB, free: 3.016 MB / 0.5137 GB Notification: Performance of FrontEnd - loaded program: time 0.0003628/0.0003628, allocations: 8 kB / 0.8146 GB, free: 14.22 MB / 0.67 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.852/0.8524, allocations: 142.3 MB / 0.9536 GB, free: 8.074 MB / 0.7169 GB Notification: Performance of NFInst.instantiate(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case680FF): time 0.2419/1.094, allocations: 193.4 MB / 1.143 GB, free: 14.27 MB / 0.9044 GB Notification: Performance of NFInst.instExpressions: time 0.0619/1.156, allocations: 35.79 MB / 1.177 GB, free: 10.41 MB / 0.9356 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01374/1.17, allocations: 230.5 kB / 1.178 GB, free: 10.18 MB / 0.9356 GB Error: Internal error Instantiation of Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case680FF failed with no error message. Notification: Performance of FrontEnd: time 0.008702/1.179, allocations: 3.17 MB / 1.181 GB, free: 7.004 MB / 0.9356 GB