Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case610.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case610,fileNamePrefix="Buildings_9_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case610",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case610,fileNamePrefix="Buildings_9_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case610",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.00106/0.00106, allocations: 99.47 kB / 15.05 MB, free: 1.105 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001147/0.001147, allocations: 177.3 kB / 15.94 MB, free: 228 kB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.505/1.505, allocations: 223.2 MB / 239.9 MB, free: 5.254 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.638/2.638, allocations: 390.3 MB / 0.6653 GB, free: 2.934 MB / 0.5137 GB Notification: Performance of FrontEnd - loaded program: time 0.0003707/0.0003707, allocations: 8 kB / 0.8146 GB, free: 14.19 MB / 0.67 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.9009/0.9013, allocations: 142.3 MB / 0.9536 GB, free: 8.078 MB / 0.7169 GB Notification: Performance of NFInst.instantiate(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case610): time 0.2527/1.154, allocations: 195.1 MB / 1.144 GB, free: 12.62 MB / 0.9044 GB Notification: Performance of NFInst.instExpressions: time 0.06943/1.224, allocations: 36.36 MB / 1.18 GB, free: 8.176 MB / 0.9356 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01472/1.238, allocations: 246.4 kB / 1.18 GB, free: 7.934 MB / 0.9356 GB Error: Internal error Instantiation of Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case610 failed with no error message. Notification: Performance of FrontEnd: time 0.008044/1.246, allocations: 2.755 MB / 1.183 GB, free: 5.172 MB / 0.9356 GB