OMSimulator --tempDir=temp_Buildings_8_Buildings_Fluid_HeatExchangers_DXCoils_BaseClasses_Examples_EvaporationPulse_fmu --startTime=0 --stopTime=7200 --timeout=50 --tolerance=1e-06 Buildings_8_Buildings_Fluid_HeatExchangers_DXCoils_BaseClasses_Examples_EvaporationPulse.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_Buildings_8_Buildings_Fluid_HeatExchangers_DXCoils_BaseClasses_Examples_EvaporationPulse_fmu" info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Fluid.HeatExchangers.DXCoils.BaseClasses.Examples.EvaporationPulse/temp_Buildings_8_Buildings_Fluid_HeatExchangers_DXCoils_BaseClasses_Examples_EvaporationPulse_fmu" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Fluid.HeatExchangers.DXCoils.BaseClasses.Examples.EvaporationPulse" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Fluid.HeatExchangers.DXCoils.BaseClasses.Examples.EvaporationPulse/temp_Buildings_8_Buildings_Fluid_HeatExchangers_DXCoils_BaseClasses_Examples_EvaporationPulse_fmu/model-azexir1b" warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/HeatExchangers/DXCoils/BaseClasses/Evaporation.mo:59: The following assertion has been violated at time 0.000000 false assert | warning | Nominal variable violating min constraint: 0.0 <= evaSho.m, has value: -3.10146 warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/HeatExchangers/DXCoils/BaseClasses/Evaporation.mo:59: The following assertion has been violated at time 0.000000 false assert | warning | Nominal variable violating min constraint: 0.0 <= evaNor.m, has value: -3.10146 warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/HeatExchangers/DXCoils/BaseClasses/Evaporation.mo:187: The following assertion has been violated during initialization at time 0.000000 evaSho.nomVal.gamma <= evaSho.gammaMax assert | warning | *** Warning: In DX coil model, gamma is too large for these coil conditions. | | | | Instead of gamma = 1.5, a value of 1.00359, which | | | | corresponds to a mass transfer effectiveness of 0.8, will be used. | | | | Coil nominal performance data are: | | | | nomVal.m_flow_nominal = 0.497018 | | | | dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00614376 - 0.00715296 = -0.0010092 | | | | QLat_flow_nominal = -1000 warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/HeatExchangers/DXCoils/BaseClasses/Evaporation.mo:173: The following assertion has been violated during initialization at time 0.000000 evaSho.dX_nominal > 1e-10 assert | warning | *** Warning: In DX coil model, dX_nominal = -0.0010092 | | | | This means that the coil is not dehumidifying air at the nominal conditions. | | | | Check nominal parameters. | | | | Nominal values: | | | | Q_flow_nominal = -5000 | | | | COP_nominal = 3 | | | | m_flow_nominal = 0.497018 | | | | TEvaIn_nominal = 292.55 (= 19.4 degC) | | | | TConIn_nominal = 308.15 (= 35 degC) | | | | phiIn_nominal = 0.5 | | | | tWet = 1400 | | | | gamma = 1.5 | | | | p_nominal = 101325 warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/HeatExchangers/DXCoils/BaseClasses/Evaporation.mo:187: The following assertion has been violated during initialization at time 0.000000 evaNor.nomVal.gamma <= evaNor.gammaMax assert | warning | *** Warning: In DX coil model, gamma is too large for these coil conditions. | | | | Instead of gamma = 1.5, a value of 1.00359, which | | | | corresponds to a mass transfer effectiveness of 0.8, will be used. | | | | Coil nominal performance data are: | | | | nomVal.m_flow_nominal = 0.497018 | | | | dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00614376 - 0.00715296 = -0.0010092 | | | | QLat_flow_nominal = -1000 warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/HeatExchangers/DXCoils/BaseClasses/Evaporation.mo:173: The following assertion has been violated during initialization at time 0.000000 evaNor.dX_nominal > 1e-10 assert | warning | *** Warning: In DX coil model, dX_nominal = -0.0010092 | | | | This means that the coil is not dehumidifying air at the nominal conditions. | | | | Check nominal parameters. | | | | Nominal values: | | | | Q_flow_nominal = -5000 | | | | COP_nominal = 3 | | | | m_flow_nominal = 0.497018 | | | | TEvaIn_nominal = 292.55 (= 19.4 degC) | | | | TConIn_nominal = 308.15 (= 35 degC) | | | | phiIn_nominal = 0.5 | | | | tWet = 1400 | | | | gamma = 1.5 | | | | p_nominal = 101325 info: maximum step size for 'model.root': 0.100000 info: Result file: model_res.mat (bufferSize=10) info: Final Statistics for 'model.root': NumSteps = 8002 NumRhsEvals = 8003 NumLinSolvSetups = 402 NumNonlinSolvIters = 8002 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 6 warnings info: 0 errors