OMSimulator --tempDir=temp_Buildings_6_0_0_Buildings_Examples_Tutorial_Boiler_System7_fmu --startTime=0 --stopTime=172800 --timeout=50 --tolerance=1e-06 Buildings_6_0_0_Buildings_Examples_Tutorial_Boiler_System7.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_Buildings_6_0_0_Buildings_Examples_Tutorial_Boiler_System7_fmu" info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_6.0.0_Buildings.Examples.Tutorial.Boiler.System7/temp_Buildings_6_0_0_Buildings_Examples_Tutorial_Boiler_System7_fmu" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_6.0.0_Buildings.Examples.Tutorial.Boiler.System7" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_6.0.0_Buildings.Examples.Tutorial.Boiler.System7/temp_Buildings_6_0_0_Buildings_Examples_Tutorial_Boiler_System7_fmu/model-79375zku" stdout | info | ... loading "tab1" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_6.0.0_Buildings.Examples.Tutorial.Boiler.System7/temp_Buildings_6_0_0_Buildings_Examples_Tutorial_Boiler_System7_fmu/model-79375zku/temp/fmu/resources/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Resources/weatherdata/USA_IL_Chicago-OHare.Intl.AP.725300_TMY3.mos" stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. assert | debug | Division by zero m_flow_turbulent / k stdout | warning | While solving non-linear system an assertion failed during initialization. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V assert | debug | Division by zero m_flow_turbulent / k assert | debug | Division by zero m_flow_turbulent / k assert | debug | Division by zero m_flow_turbulent / k assert | debug | Division by zero m_flow_turbulent / k assert | debug | Division by zero m_flow_turbulent / k assert | debug | Division by zero m_flow_turbulent / k assert | debug | Solving non-linear system 398 failed at time=0. | | | | For more information please use -lv LOG_NLS. assert | error | Failed to solve the initialization problem with global homotopy with equidistant step size. assert | debug | Unable to solve initialization problem. error: [fmi2logger] fmu (logFmi2Call): fmi2EnterInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.fmu" error: [initialize] Initialization of system "model.root" failed error: [simulate] Model "model" is in wrong model state info: 0 warnings info: 4 errors