startTime=0 stopTime=250 tolerance=1e-09 numberOfIntervals=2500 stepSize=0.1 Regular simulation: ./ThermoPower_ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV2ph_C -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0166408s reading init.xml | | | | | | 0.00194896s reading info.xml | | | | | | 0.000162294s [ 0.0%] pre-initialization | | | | | | 0.0169707s [ 0.2%] initialization | | | | | | 0.000206297s [ 0.0%] steps | | | | | | 0.0226644s [ 0.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00520032s [ 0.0%] event-handling | | | | | | 0.0265148s [ 0.2%] overhead | | | | | | 10.7462s [ 99.3%] simulation | | | | | | 10.8179s [100.0%] total | | | | | events | | | | | | 6 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 5584 steps taken | | | | | | 8013 calls of functionODE | | | | | | 968 evaluations of jacobian | | | | | | 374 error test failures | | | | | | 0 convergence test failures | | | | | | 6.27797s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.