Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr SiemensPower_OMCtest_SiemensPower.Components.Valves.Tests.valve_test.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.1.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 1.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower OMCtest/package.mo", uses=false) Using package SiemensPower with version OMCtest (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower OMCtest/package.mo) Using package ModelicaServices with version 1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 1.0.0/package.mo) Using package Modelica with version 3.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.1.0+maint.om/package.mo) Running command: translateModel(SiemensPower.Components.Valves.Tests.valve_test,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="SiemensPower_OMCtest_SiemensPower.Components.Valves.Tests.valve_test") translateModel(SiemensPower.Components.Valves.Tests.valve_test,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="SiemensPower_OMCtest_SiemensPower.Components.Valves.Tests.valve_test") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.1.0+maint.om/package.mo): time 0.8023/0.8023, allocations: 110.9 MB / 125.9 MB, free: 6.199 MB / 106.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 1.0.0/package.mo): time 0.001914/0.001914, allocations: 146.5 kB / 151.8 MB, free: 4.973 MB / 122.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower OMCtest/package.mo): time 0.02077/0.02077, allocations: 4.018 MB / 181.7 MB, free: 7.039 MB / 154.7 MB Notification: Performance of FrontEnd - loaded program: time 0.000336/0.0003361, allocations: 12.69 kB / 217 MB, free: 42.81 MB / 170.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.05473/0.05508, allocations: 26.11 MB / 243.1 MB, free: 16.87 MB / 170.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 4.286/4.341, allocations: 1.81 GB / 2.047 GB, free: 57.3 MB / 250.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0001563/4.342, allocations: 45.23 kB / 2.047 GB, free: 57.28 MB / 250.7 MB Notification: Performance of FrontEnd - DAE generated: time 2.45/6.792, allocations: 0.5911 GB / 2.638 GB, free: 16.01 MB / 282.7 MB Notification: Performance of FrontEnd: time 2.554e-06/6.792, allocations: 7.25 kB / 2.638 GB, free: 16.01 MB / 282.7 MB Notification: Performance of Transformations before backend: time 8.593e-05/6.792, allocations: 24.47 kB / 2.638 GB, free: 16.01 MB / 282.7 MB Error: Too few equations, under-determined system. The model has 237 equation(s) and 239 variable(s). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower OMCtest/Boundaries/GasSinkP.mo:24:3-28:24:writable] Warning: Variable gasSinkP.Xi_In[1] does not have any remaining equation to be solved in. The original equations were: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower OMCtest/Boundaries/GasSourceP.mo:31:3-35:24:writable] Warning: Variable gasSourceP.Xi_In[1] does not have any remaining equation to be solved in. The original equations were: