Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerSystems_cpp_PowerSystems.Examples.AC1ph_DC.Drives.BLDC.conf.json loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo", uses=false) Using package PowerSystems with version 1.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo) Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: translateModel(PowerSystems.Examples.AC1ph_DC.Drives.BLDC,tolerance=1e-05,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="PowerSystems_cpp_PowerSystems.Examples.AC1ph_DC.Drives.BLDC") translateModel(PowerSystems.Examples.AC1ph_DC.Drives.BLDC,tolerance=1e-05,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="PowerSystems_cpp_PowerSystems.Examples.AC1ph_DC.Drives.BLDC") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001615/0.001614, allocations: 181.8 kB / 15.76 MB, free: 6.344 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.932/1.932, allocations: 205.4 MB / 221.9 MB, free: 13.68 MB / 186.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001472/0.001472, allocations: 98.73 kB / 270.3 MB, free: 13.21 MB / 234.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo): time 0.2962/0.2962, allocations: 38.05 MB / 356.6 MB, free: 0.7656 MB / 250.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0004342/0.0004343, allocations: 8 kB / 422.7 MB, free: 26.42 MB / 282.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1149/0.1153, allocations: 56.32 MB / 479 MB, free: 2.035 MB / 314.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.5416/0.657, allocations: 118.4 MB / 0.5834 GB, free: 13.58 MB / 394.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003403/0.6574, allocations: 96.33 kB / 0.5835 GB, free: 13.53 MB / 394.7 MB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/AC1ph_DC/Drives.mo:141:5-142:74:writable] Error: Variable bldcm.inverter: In modifier (modulation = 3), class or component modulation not found in . [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/AC1ph_DC/Drives.mo:141:5-142:74:writable] Error: Variable bldcm.inverter: In modifier (modulation = 3), class or component modulation not found in . Error: Error occurred while flattening model PowerSystems.Examples.AC1ph_DC.Drives.BLDC Notification: Performance of FrontEnd: time 0.03731/0.6947, allocations: 6.565 MB / 0.5899 GB, free: 7.926 MB / 394.7 MB