Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerSystems_PowerSystems.Examples.Wind.WindTurbine_DFIG.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo", uses=false) Using package PowerSystems with version 1.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo) Using package ModelicaServices with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo) Using package Modelica with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo) Using package Complex with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo) Running command: translateModel(PowerSystems.Examples.Wind.WindTurbine_DFIG,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="PowerSystems_PowerSystems.Examples.Wind.WindTurbine_DFIG") translateModel(PowerSystems.Examples.Wind.WindTurbine_DFIG,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="PowerSystems_PowerSystems.Examples.Wind.WindTurbine_DFIG") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo): time 0.0009876/0.0009877, allocations: 179.5 kB / 16.38 MB, free: 5.762 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo): time 1.169/1.169, allocations: 194.5 MB / 211.6 MB, free: 3.059 MB / 170.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo): time 0.001627/0.001627, allocations: 117.5 kB / 256.9 MB, free: 4.34 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo): time 0.1592/0.1592, allocations: 38 MB / 340.1 MB, free: 1.371 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0003256/0.0003256, allocations: 16 kB / 403.8 MB, free: 68.82 MB / 314.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.0711/0.07144, allocations: 53.23 MB / 457 MB, free: 15.57 MB / 314.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.2876/0.3591, allocations: 132.9 MB / 0.5761 GB, free: 11.42 MB / 394.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002194/0.3594, allocations: 92.14 kB / 0.5762 GB, free: 11.38 MB / 394.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/AC3ph/Machines.mo:2208:3-2208:47:writable] Error: Could not evaluate structural parameter (or constant): n_r which gives dimensions of array: L_r[n_r]. Array dimensions must be known at compile time. Error: Error occurred while flattening model PowerSystems.Examples.Wind.WindTurbine_DFIG Notification: Performance of FrontEnd: time 0.07041/0.4298, allocations: 25.25 MB / 0.6008 GB, free: 5.488 MB / 410.7 MB