Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerSystems_PowerSystems.Examples.AC1ph_DC.Drives.BLDC.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo", uses=false) Using package PowerSystems with version 1.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo) Using package ModelicaServices with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo) Using package Modelica with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo) Using package Complex with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo) Running command: translateModel(PowerSystems.Examples.AC1ph_DC.Drives.BLDC,tolerance=1e-05,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="PowerSystems_PowerSystems.Examples.AC1ph_DC.Drives.BLDC") translateModel(PowerSystems.Examples.AC1ph_DC.Drives.BLDC,tolerance=1e-05,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="PowerSystems_PowerSystems.Examples.AC1ph_DC.Drives.BLDC") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo): time 0.001041/0.001041, allocations: 179.3 kB / 16.38 MB, free: 5.766 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo): time 1.206/1.206, allocations: 194.5 MB / 211.6 MB, free: 3.047 MB / 170.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo): time 0.001668/0.001668, allocations: 121.9 kB / 256.9 MB, free: 4.375 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo): time 0.1634/0.1634, allocations: 37.99 MB / 340.1 MB, free: 1.363 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0003417/0.0003418, allocations: 8 kB / 403.8 MB, free: 68.81 MB / 314.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.08542/0.08578, allocations: 53.23 MB / 457 MB, free: 15.57 MB / 314.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.3253/0.4112, allocations: 113.2 MB / 0.5568 GB, free: 14.33 MB / 378.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003247/0.4115, allocations: 109.1 kB / 0.5569 GB, free: 14.27 MB / 378.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/AC1ph_DC/Drives.mo:141:5-142:74:writable] Error: Variable bldcm.inverter: In modifier (modulation = 3), class or component modulation not found in . [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/AC1ph_DC/Drives.mo:141:5-142:74:writable] Error: Variable bldcm.inverter: In modifier (modulation = 3), class or component modulation not found in . Error: Error occurred while flattening model PowerSystems.Examples.AC1ph_DC.Drives.BLDC Notification: Performance of FrontEnd: time 0.01653/0.4281, allocations: 6.522 MB / 0.5633 GB, free: 8.695 MB / 378.7 MB