Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.TestTwoBusesTwoLinesOneLoadOneBreakerOpenClosePortB.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: translateModel(PowerGrids.Electrical.Test.TestTwoBusesTwoLinesOneLoadOneBreakerOpenClosePortB,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.TestTwoBusesTwoLinesOneLoadOneBreakerOpenClosePortB") translateModel(PowerGrids.Electrical.Test.TestTwoBusesTwoLinesOneLoadOneBreakerOpenClosePortB,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.TestTwoBusesTwoLinesOneLoadOneBreakerOpenClosePortB") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.009658/0.009658, allocations: 170.8 kB / 15.11 MB, free: 5.969 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.333/1.333, allocations: 205.4 MB / 221.3 MB, free: 13.82 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008488/0.0008488, allocations: 82.86 kB / 269.6 MB, free: 13.34 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo): time 0.05311/0.05311, allocations: 14.17 MB / 332 MB, free: 8.73 MB / 234.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0003698/0.0003698, allocations: 9.188 kB / 393.6 MB, free: 51.13 MB / 282.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.09611/0.0965, allocations: 51.12 MB / 444.7 MB, free: 6.859 MB / 282.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.1101/0.2066, allocations: 86.01 MB / 0.5183 GB, free: 0.7344 MB / 362.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002467/0.2069, allocations: 83.95 kB / 0.5184 GB, free: 0.6523 MB / 362.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$infiniteBus1$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.TestTwoBusesTwoLinesOneLoadOneBreakerOpenClosePortB Notification: Performance of FrontEnd: time 0.2022/0.4091, allocations: 5.646 MB / 0.5239 GB, free: 83.64 MB / 362.7 MB