Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.TestTransformerFixedRatio.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: translateModel(PowerGrids.Electrical.Test.TestTransformerFixedRatio,tolerance=1e-06,outputFormat="empty",numberOfIntervals=100,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.TestTransformerFixedRatio") translateModel(PowerGrids.Electrical.Test.TestTransformerFixedRatio,tolerance=1e-06,outputFormat="empty",numberOfIntervals=100,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.TestTransformerFixedRatio") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.004704/0.004703, allocations: 172 kB / 15.11 MB, free: 5.98 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.37/1.37, allocations: 205.4 MB / 221.3 MB, free: 13.84 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0007995/0.0007993, allocations: 90.86 kB / 269.6 MB, free: 13.37 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo): time 0.05394/0.05393, allocations: 14.17 MB / 332 MB, free: 8.754 MB / 234.7 MB Notification: Performance of FrontEnd - loaded program: time 0.000364/0.000364, allocations: 13.38 kB / 393.6 MB, free: 51.22 MB / 282.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1059/0.1062, allocations: 51.13 MB / 444.7 MB, free: 6.895 MB / 282.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.1179/0.2242, allocations: 84.85 MB / 0.5172 GB, free: 1.926 MB / 362.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002461/0.2245, allocations: 75.97 kB / 0.5173 GB, free: 1.852 MB / 362.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$infiniteBus$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.TestTransformerFixedRatio Notification: Performance of FrontEnd: time 0.2257/0.4503, allocations: 5.607 MB / 0.5227 GB, free: 83.1 MB / 362.7 MB