Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.SynchronousMachine4WindingsExact.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Ignoring simflag -noemit -homotopyOnFirstTry=() since it seems broken on HelloWorld Running command: translateModel(PowerGrids.Electrical.Test.SynchronousMachine4WindingsExact,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.SynchronousMachine4WindingsExact") translateModel(PowerGrids.Electrical.Test.SynchronousMachine4WindingsExact,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.SynchronousMachine4WindingsExact") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.005872/0.005871, allocations: 169.6 kB / 15.11 MB, free: 5.973 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.528/1.528, allocations: 205.4 MB / 221.3 MB, free: 13.84 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009198/0.0009195, allocations: 102.8 kB / 269.6 MB, free: 13.36 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo): time 0.05334/0.05334, allocations: 14.16 MB / 332 MB, free: 8.758 MB / 234.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0003375/0.0003376, allocations: 10.78 kB / 395 MB, free: 50.48 MB / 282.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.09684/0.09719, allocations: 51.12 MB / 446.1 MB, free: 5.547 MB / 282.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.3365/0.4338, allocations: 90.59 MB / 0.5241 GB, free: 31.33 MB / 362.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002534/0.4341, allocations: 76.22 kB / 0.5242 GB, free: 31.33 MB / 362.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$bus$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.SynchronousMachine4WindingsExact Notification: Performance of FrontEnd: time 0.01391/0.448, allocations: 5.684 MB / 0.5297 GB, free: 30.58 MB / 362.7 MB