Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.OneBusImpedanceOneLoad.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: translateModel(PowerGrids.Electrical.Test.OneBusImpedanceOneLoad,tolerance=1e-06,outputFormat="empty",numberOfIntervals=100,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.OneBusImpedanceOneLoad") translateModel(PowerGrids.Electrical.Test.OneBusImpedanceOneLoad,tolerance=1e-06,outputFormat="empty",numberOfIntervals=100,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.OneBusImpedanceOneLoad") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.006946/0.006946, allocations: 169.5 kB / 15.11 MB, free: 5.973 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.435/1.435, allocations: 205.4 MB / 221.3 MB, free: 13.83 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008464/0.0008464, allocations: 94.8 kB / 269.6 MB, free: 13.37 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo): time 0.05466/0.05466, allocations: 14.17 MB / 332 MB, free: 8.758 MB / 234.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0003146/0.0003146, allocations: 12.62 kB / 393.6 MB, free: 51.21 MB / 282.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1072/0.1075, allocations: 51.13 MB / 444.7 MB, free: 6.898 MB / 282.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.1155/0.223, allocations: 82.93 MB / 0.5153 GB, free: 3.852 MB / 362.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002752/0.2234, allocations: 75.91 kB / 0.5154 GB, free: 3.777 MB / 362.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$infiniteBus$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.OneBusImpedanceOneLoad Notification: Performance of FrontEnd: time 0.2292/0.4526, allocations: 7.849 MB / 0.523 GB, free: 82.2 MB / 362.7 MB