Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr IDEAS_dev_IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package IDEAS with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Running command: translateModel(IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IDEAS_dev_IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week") translateModel(IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IDEAS_dev_IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.007835/0.007835, allocations: 172.4 kB / 15.12 MB, free: 5.973 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/package.mo): time 0.7405/0.7405, allocations: 135.2 MB / 151.1 MB, free: 13.81 MB / 122.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.46/1.46, allocations: 223.2 MB / 406.9 MB, free: 3.211 MB / 330.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009188/0.0009187, allocations: 105.2 kB / 489.9 MB, free: 10.92 MB / 362.7 MB Notification: Performance of FrontEnd - loaded program: time 0.000323/0.000323, allocations: 15.94 kB / 0.5691 GB, free: 14.14 MB / 458.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.428/0.4284, allocations: 82.3 MB / 0.6495 GB, free: 36.14 MB / 458.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.1807/0.6091, allocations: 143.7 MB / 0.7898 GB, free: 4.227 MB / 0.5573 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003113/0.6095, allocations: 111.9 kB / 0.7899 GB, free: 4.117 MB / 0.5573 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/GroundTemperatureResponse.mo:8:3-10:87:writable] Error: Array equation has unknown size in groTemRes.borFieDat.conDat.cooBor=borFieDat.conDat.cooBor. Error: Internal error - InstUtil.moveBindings: Mismatched number of equations and variables. Error: Error occurred while flattening model IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week Notification: Performance of FrontEnd: time 0.5274/1.137, allocations: 34.23 MB / 0.8234 GB, free: 122.5 MB / 0.5573 GB