Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr IDEAS_dev_IDEAS.Fluid.Chillers.Validation.Carnot_TEva_2ndLaw.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package IDEAS with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Running command: translateModel(IDEAS.Fluid.Chillers.Validation.Carnot_TEva_2ndLaw,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IDEAS_dev_IDEAS.Fluid.Chillers.Validation.Carnot_TEva_2ndLaw") translateModel(IDEAS.Fluid.Chillers.Validation.Carnot_TEva_2ndLaw,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IDEAS_dev_IDEAS.Fluid.Chillers.Validation.Carnot_TEva_2ndLaw") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.004702/0.004702, allocations: 169.3 kB / 15.11 MB, free: 5.582 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/package.mo): time 0.9146/0.9146, allocations: 135.2 MB / 151.1 MB, free: 13.82 MB / 122.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.511/1.511, allocations: 223.2 MB / 406.9 MB, free: 3.223 MB / 330.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009809/0.0009808, allocations: 96.19 kB / 489.9 MB, free: 10.93 MB / 362.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0003814/0.0003815, allocations: 12 kB / 0.5691 GB, free: 14.18 MB / 458.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5619/0.5623, allocations: 82.31 MB / 0.6495 GB, free: 36.17 MB / 458.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.8589/1.421, allocations: 398 MB / 1.038 GB, free: 8.879 MB / 0.6823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002993/1.422, allocations: 95.52 kB / 1.038 GB, free: 8.828 MB / 0.6823 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Fluid/Chillers/Validation/Carnot_TEva_2ndLaw.mo:81:5-96:72:writable] Error: Variable chi_b.chi: Cyclically dependent constants or parameters found in scope IDEAS.Fluid.Chillers.Carnot_TEva$chi_b$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model IDEAS.Fluid.Chillers.Validation.Carnot_TEva_2ndLaw Notification: Performance of FrontEnd: time 0.8351/2.257, allocations: 217.4 MB / 1.251 GB, free: 71.88 MB / 0.6823 GB