Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr IDEAS_IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package IDEAS with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Running command: translateModel(IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IDEAS_IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years") translateModel(IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IDEAS_IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.008022/0.008022, allocations: 170.8 kB / 15.11 MB, free: 5.973 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/package.mo): time 0.7823/0.7823, allocations: 132.3 MB / 148.1 MB, free: 244 kB / 106.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.455/1.455, allocations: 223.2 MB / 403.2 MB, free: 6.781 MB / 330.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009306/0.0009306, allocations: 95.17 kB / 485.5 MB, free: 14.18 MB / 362.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0003942/0.0003943, allocations: 8 kB / 0.5641 GB, free: 2.125 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3994/0.3998, allocations: 81.58 MB / 0.6438 GB, free: 39.31 MB / 458.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.1895/0.5894, allocations: 142.4 MB / 0.7828 GB, free: 9.539 MB / 0.5573 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002977/0.5897, allocations: 111.9 kB / 0.7829 GB, free: 9.43 MB / 0.5573 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/GroundTemperatureResponse.mo:8:3-10:87:writable] Error: Array equation has unknown size in groTemRes.borFieDat.conDat.cooBor=borFieDat.conDat.cooBor. Error: Internal error - InstUtil.moveBindings: Mismatched number of equations and variables. Error: Error occurred while flattening model IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years Notification: Performance of FrontEnd: time 0.3799/0.9697, allocations: 11.97 MB / 0.7946 GB, free: 136.1 MB / 0.5573 GB