Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr IBPSA_latest_IBPSA.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package IBPSA with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Running command: translateModel(IBPSA.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator,tolerance=1e-08,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IBPSA_latest_IBPSA.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator") translateModel(IBPSA.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator,tolerance=1e-08,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IBPSA_latest_IBPSA.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.00155/0.00155, allocations: 183.9 kB / 15.76 MB, free: 6.363 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/package.mo): time 0.535/0.535, allocations: 91.99 MB / 108.5 MB, free: 13.05 MB / 90.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.573/1.573, allocations: 223.2 MB / 354.3 MB, free: 12.15 MB / 282.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.00111/0.00111, allocations: 100.3 kB / 427.4 MB, free: 3.895 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0003516/0.0003517, allocations: 12 kB / 0.4982 GB, free: 42.27 MB / 362.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1459/0.1463, allocations: 72.31 MB / 0.5689 GB, free: 1.895 MB / 394.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 5.852/5.998, allocations: 2.207 GB / 2.776 GB, free: 101 MB / 0.6042 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002752/5.999, allocations: 103.8 kB / 2.776 GB, free: 101 MB / 0.6042 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/Fluid/Movers/BaseClasses/Euler/getPeak.mo:9:3-10:49:writable] Warning: Component peak in env: IBPSA.Fluid.Movers.BaseClasses.Euler.getPeak has the same name as its type IBPSA.Fluid.Movers.BaseClasses.Euler.peak. This is forbidden by Modelica specification and may lead to lookup errors. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/Fluid/Movers/Data/Generic.mo:90:3-92:29:writable] Error: Class IBPSA.Fluid.Movers.BaseClasses.Euler.getPeak not found in scope IBPSA.Fluid.Movers.Data.Generic (looking for a function or record). Error: Error occurred while flattening model IBPSA.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator Notification: Performance of FrontEnd: time 3.402/9.4, allocations: 0.9615 GB / 3.738 GB, free: 75.02 MB / 0.6198 GB