Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr IBPSA_latest_IBPSA.Fluid.HeatExchangers.Examples.WaterCooler_T.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package IBPSA with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Running command: translateModel(IBPSA.Fluid.HeatExchangers.Examples.WaterCooler_T,tolerance=1e-08,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IBPSA_latest_IBPSA.Fluid.HeatExchangers.Examples.WaterCooler_T") translateModel(IBPSA.Fluid.HeatExchangers.Examples.WaterCooler_T,tolerance=1e-08,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IBPSA_latest_IBPSA.Fluid.HeatExchangers.Examples.WaterCooler_T") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001292/0.001292, allocations: 182.9 kB / 15.76 MB, free: 6.359 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/package.mo): time 0.5238/0.5238, allocations: 92 MB / 108.5 MB, free: 13.07 MB / 90.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.698/1.698, allocations: 223.2 MB / 354.3 MB, free: 12.18 MB / 282.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001011/0.001011, allocations: 104.2 kB / 427.4 MB, free: 3.914 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0005443/0.0005443, allocations: 8 kB / 0.4983 GB, free: 42.3 MB / 362.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2098/0.2104, allocations: 72.3 MB / 0.5689 GB, free: 1.93 MB / 394.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 1.156/1.367, allocations: 418.4 MB / 0.9775 GB, free: 47.16 MB / 0.5886 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002918/1.367, allocations: 96.83 kB / 0.9775 GB, free: 47.11 MB / 0.5886 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/Fluid/Movers/BaseClasses/Euler/getPeak.mo:9:3-10:49:writable] Warning: Component peak in env: IBPSA.Fluid.Movers.BaseClasses.Euler.getPeak has the same name as its type IBPSA.Fluid.Movers.BaseClasses.Euler.peak. This is forbidden by Modelica specification and may lead to lookup errors. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/Fluid/Movers/Data/Generic.mo:90:3-92:29:writable] Error: Class IBPSA.Fluid.Movers.BaseClasses.Euler.getPeak not found in scope IBPSA.Fluid.Movers.Data.Generic (looking for a function or record). Error: Error occurred while flattening model IBPSA.Fluid.HeatExchangers.Examples.WaterCooler_T Notification: Performance of FrontEnd: time 0.7667/2.134, allocations: 203.6 MB / 1.176 GB, free: 105 MB / 0.6042 GB