startTime=0 stopTime=0.05 tolerance=1e-06 numberOfIntervals=500 stepSize=0.0001 Regular simulation: ./FluxTubesExtension_FluxTubesExtension.Examples.ToroidalCoreAirgap -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00150248s reading init.xml | | | | | | 0.000121558s reading info.xml | | | | | | 5.9672e-05s [ 2.0%] pre-initialization | | | | | | 7.7154e-05s [ 2.5%] initialization | | | | | | 1.793e-06s [ 0.1%] steps | | | | | | 7.71e-07s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 6.6135e-05s [ 2.2%] event-handling | | | | | | 0.000321511s [ 10.5%] overhead | | | | | | 0.00252652s [ 82.7%] simulation | | | | | | 0.00305356s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 1705 steps taken | | | | | | 1705 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.