Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSummer.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSummer,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSummer") translateModel(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSummer,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSummer") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.817/1.817, allocations: 288.3 MB / 303.2 MB, free: 8.078 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001302/0.001302, allocations: 170.2 kB / 371.8 MB, free: 10.29 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.852/1.852, allocations: 205.4 MB / 0.6306 GB, free: 10.02 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009971/0.000997, allocations: 94.91 kB / 0.7439 GB, free: 5.941 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0004596/0.0004596, allocations: 18.98 kB / 0.8668 GB, free: 142.2 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.311/0.3115, allocations: 115.3 MB / 0.9794 GB, free: 27.71 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.131/6.442, allocations: 2.132 GB / 3.112 GB, free: 133.5 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003446/6.443, allocations: 110.9 kB / 3.112 GB, free: 133.4 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSummer Notification: Performance of FrontEnd: time 6.494/12.94, allocations: 1.634 GB / 4.745 GB, free: 116.4 MB / 0.9948 GB