Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600") translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.78/1.78, allocations: 288.3 MB / 303.2 MB, free: 8.168 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001129/0.001129, allocations: 192 kB / 371.8 MB, free: 10.3 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.803/1.803, allocations: 205.4 MB / 0.6306 GB, free: 10.07 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008726/0.0008727, allocations: 93.16 kB / 0.7439 GB, free: 5.98 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0004681/0.0004681, allocations: 11.25 kB / 0.8668 GB, free: 142.2 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2837/0.2842, allocations: 115.3 MB / 0.9794 GB, free: 27.72 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.421/6.705, allocations: 2.249 GB / 3.229 GB, free: 10.53 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004045/6.705, allocations: 119.3 kB / 3.229 GB, free: 10.46 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case600FF.mo:199:3-207:69:writable] Error: Variable staRes: In modifier (minT(Min = 254.35), class or component Min), class or component minT not found in . Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600 Notification: Performance of FrontEnd: time 1.114/7.819, allocations: 231.4 MB / 3.455 GB, free: 165.8 MB / 0.948 GB