Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: translateModel(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|supPosErr",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition") translateModel(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|supPosErr",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.327/1.327, allocations: 251.9 MB / 266.9 MB, free: 11.02 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001052/0.001052, allocations: 178 kB / 326.5 MB, free: 2.238 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.664/1.664, allocations: 205.4 MB / 0.5775 GB, free: 20.23 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009614/0.0009615, allocations: 98.3 kB / 0.6821 GB, free: 12.88 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.000356/0.000356, allocations: 10.53 kB / 0.7963 GB, free: 135.1 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1971/0.1975, allocations: 106.3 MB / 0.9001 GB, free: 63.89 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.1681/0.3656, allocations: 131.9 MB / 1.029 GB, free: 11.86 MB / 0.6823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002956/0.366, allocations: 103.9 kB / 1.029 GB, free: 11.75 MB / 0.6823 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/LoadAggregation/Validation/TemporalSuperposition.mo:5:3-9:41:writable] Error: No matching function found for Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.temporalSuperposition(6, {2.0, 1000000.0, 3.0, 1000000.0, 1000000.0}, {0.4, 0.0, 0.2, 1.0, 0.0}, 3) of type .Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.temporalSuperposition(Integer i, Real(quantity = "Power", unit = "W")[i] QAgg_flow, Real(quantity = "ThermalResistance", unit = "K/W")[i] kappa, Integer curCel) => Real(quantity = "ThermodynamicTemperature", unit = "K") in component candidates are .Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.temporalSuperposition(Integer i, Real(quantity = "Power", unit = "W")[i] QAgg_flow, Real(quantity = "ThermalResistance", unit = "K/W")[i] kappa, Integer curCel) => Real(quantity = "ThermodynamicTemperature", unit = "K") Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition Notification: Performance of FrontEnd: time 0.0009115/0.3669, allocations: 0.5013 MB / 1.029 GB, free: 11.25 MB / 0.6823 GB